Durability of Fiber-Reinforced Polymer Composites in Harsh Civil Infrastructure Environments: Mechanisms, Prediction and Design

Fiber-reinforced polymer (FRP) composites do not corrode, so engineers use them where steel fails. Their weak point is long-term behavior in hot, wet, alkaline and salty settings. This review covers 100 studies from 1998 to 2026 and five design documents on FRP bars, laminates and bonded systems. We grade the evidence and separate measured results from model predictions. Moisture, alkali, heat, ultraviolet light, freeze–thaw cycles and sustained stress damage the resin, the fiber–matrix interface and, in glass and basalt FRP, the fibers. Retention values cannot rank materials unless product, exposure and test method match. In one study with identical conditions, glass FRP bars kept 43.1% and carbon FRP bars 84.9% of their tensile strength after 180 days at 60 °C in pore solution. Other glass FRP values of 43–58% come from different products, solutions, stress levels and durations. In bonded systems, the adhesive and the substrate often control the losses. Arrhenius extrapolation holds only if one mechanism acts across the test temperatures. The activation energies in the one glass FRP bar study we could verify in full are low (19–27 kJ/mol), so a 180-day test at 60 °C covers about 1.3 years at 30 °C. Machine learning (ML) models report R2 up to 0.98, but the datasets are small, the validation differs and the results do not compare across tasks. The physics-informed ML workflow we propose is a concept that no study has validated. ACI CODE-440.11-22 sets the environmental reduction factor (CE) for glass FRP bars at 0.85, and none of the documents we reviewed sets CE as an explicit function of service temperature. We list research needs for hot-arid and coastal climates.

Authors

Institutions

Publication Details

Journal
Polymers
Published
2026-11-16
DOI
https://doi.org/10.3390/polym18222874
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Durability of Fiber-Reinforced Polymer Composites in Harsh Civil Infrastructure Environments: Mechanisms, Prediction and Design

Sayeed Rushd, Md Arifuzzaman, Ziad Nayef Shatnawi, Sourov Paul et al.
1 links
Polymers
Structural Behavior of Reinforced Concrete
article

Durability of Fiber-Reinforced Polymer Composites in Harsh Civil Infrastructure Environments: Mechanisms, Prediction and Design

Sayeed Rushd, Md Arifuzzaman, Ziad Nayef Shatnawi, Sourov Paul, Muhammad Ali Martuza, Mohammad Anwar Parvez, Abdullah Al Mamun
article en

Abstract

Fiber-reinforced polymer (FRP) composites do not corrode, so engineers use them where steel fails. Their weak point is long-term behavior in hot, wet, alkaline and salty settings. This review covers 100 studies from 1998 to 2026 and five design documents on FRP bars, laminates and bonded systems. We grade the evidence and separate measured results from model predictions. Moisture, alkali, heat, ultraviolet light, freeze–thaw cycles and sustained stress damage the resin, the fiber–matrix interface and, in glass and basalt FRP, the fibers. Retention values cannot rank materials unless product, exposure and test method match. In one study with identical conditions, glass FRP bars kept 43.1% and carbon FRP bars 84.9% of their tensile strength after 180 days at 60 °C in pore solution. Other glass FRP values of 43–58% come from different products, solutions, stress levels and durations. In bonded systems, the adhesive and the substrate often control the losses. Arrhenius extrapolation holds only if one mechanism acts across the test temperatures. The activation energies in the one glass FRP bar study we could verify in full are low (19–27 kJ/mol), so a 180-day test at 60 °C covers about 1.3 years at 30 °C. Machine learning (ML) models report R2 up to 0.98, but the datasets are small, the validation differs and the results do not compare across tasks. The physics-informed ML workflow we propose is a concept that no study has validated. ACI CODE-440.11-22 sets the environmental reduction factor (CE) for glass FRP bars at 0.85, and none of the documents we reviewed sets CE as an explicit function of service temperature. We list research needs for hot-arid and coastal climates.

PolymersVol. 18(22)
Qassim University (SA), Leading University (BD), Purdue University West Lafayette (US), Purdue University System (US), King Faisal University (SA)
King Faisal University
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon