Model bias and calibration uncertainty in dispersive interrogation of fiber-optic Fabry–Perot sensors

Abstract Dispersive interrogation converts Fabry–Perot spectra into temporal waveforms, but cavity-length estimates depend on both the propagation approximation and the calibration of the time–wavelength coordinate. We formulate a coherent two-beam forward model retaining relative delay, reflection phase, second- and third-order dispersion, and detector bandwidth. Variable projection removes pulse-dependent gain and offset, yielding a local expression that relates waveform mismatch to length bias and propagates correlated calibration uncertainties. An information analysis quantifies the contribution of an independent phase observation. In a controlled 50 μm cavity simulation at a signal-to-noise ratio of 60 dB, 200 trials give root-mean-square length errors of 7.980, 0.0279 and 0.0060 nm for linear intensity mapping, nonlinear intensity mapping and field-template estimation, respectively, with calibration parameters fixed at their true values. The corresponding local standard-deviation bound increases from 0.0060 to 2.548 nm when reflection phase is unknown. Separate measurements test coordinate calibration against an optical spectrum analyser. For an unloaded stainless-steel specimen, a dispersion-constrained local linear mapping reduces the normalized spectral residual from 7.44% to 3.93% and the validation-peak wavelength discrepancy from 0.317 to 0.053 nm. For a sapphire specimen, physical nonlinear mapping reduces spectral residuals from 6.32–6.63% to 4.94–5.18% in two static validation windows; empirical quadratic calibration gives 4.67–4.94%. The results separate errors due to reference-wavelength scaling, mapping curvature and finite-dispersion propagation, and quantify the phase calibration needed to benefit from a coherent estimator.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2026-11-16
DOI
https://doi.org/10.1088/1361-6501/aec28a
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Model bias and calibration uncertainty in dispersive interrogation of fiber-optic Fabry–Perot sensors

Zhaolin Zhu, Jun Yang, Wenxiang Liu, Dezhi Zhang et al.
Measurement Science and Technology
Advanced Fiber Optic Sensors
article

Model bias and calibration uncertainty in dispersive interrogation of fiber-optic Fabry–Perot sensors

Zhaolin Zhu, Jun Yang, Wenxiang Liu, Dezhi Zhang, Zhenyu Wang, Hang Zheng, Bin Chen
article en

Abstract

Abstract Dispersive interrogation converts Fabry–Perot spectra into temporal waveforms, but cavity-length estimates depend on both the propagation approximation and the calibration of the time–wavelength coordinate. We formulate a coherent two-beam forward model retaining relative delay, reflection phase, second- and third-order dispersion, and detector bandwidth. Variable projection removes pulse-dependent gain and offset, yielding a local expression that relates waveform mismatch to length bias and propagates correlated calibration uncertainties. An information analysis quantifies the contribution of an independent phase observation. In a controlled 50 μm cavity simulation at a signal-to-noise ratio of 60 dB, 200 trials give root-mean-square length errors of 7.980, 0.0279 and 0.0060 nm for linear intensity mapping, nonlinear intensity mapping and field-template estimation, respectively, with calibration parameters fixed at their true values. The corresponding local standard-deviation bound increases from 0.0060 to 2.548 nm when reflection phase is unknown. Separate measurements test coordinate calibration against an optical spectrum analyser. For an unloaded stainless-steel specimen, a dispersion-constrained local linear mapping reduces the normalized spectral residual from 7.44% to 3.93% and the validation-peak wavelength discrepancy from 0.317 to 0.053 nm. For a sapphire specimen, physical nonlinear mapping reduces spectral residuals from 6.32–6.63% to 4.94–5.18% in two static validation windows; empirical quadratic calibration gives 4.67–4.94%. The results separate errors due to reference-wavelength scaling, mapping curvature and finite-dispersion propagation, and quantify the phase calibration needed to benefit from a coherent estimator.

Measurement Science and Technology
Northwest Institute of Nuclear Technology (CN), Zhejiang University (CN)
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon