Sensor-skin contact pressure as a hidden confounder in wearable photoplethysmography biosensing

Photoplethysmography (PPG) is increasingly used for cuffless blood pressure (BP) monitoring and wearable cardiovascular sensing. However, the reliability of PPG-derived digital biomarkers is highly sensitive to sensor–skin contact pressure, which influences optical coupling, vascular compression, and motion susceptibility. Despite its importance, contact pressure is often poorly controlled or insufficiently reported, introducing a hidden source of variability that can compromise signal integrity, downstream model performance, and the reproducibility of wearable BP systems. Here, we systematically review experimental evidence on the influence of contact pressure in PPG-based cuffless BP estimation. Across 29 studies of PPG acquisition, BP estimation, and related pulse sensing, those that examined contact loading reported the following qualitative patterns: insufficient pressure reduced optical stability and increased motion artefacts, whereas excessive pressure compressed superficial vasculature, attenuated systolic peaks, and suppressed the dicrotic notch. Within studies that varied contact loading, favourable conditions depended on the anatomical site, sensor, and outcome; better waveform quality did not by itself establish lower BP-estimation error or a universal pressure target. Low, moderate, and high loading conditions are therefore used only as study-defined descriptions of signal-level effects. Because reported performance metrics represented different statistical constructs, outcomes were summarized separately for signal quality, waveform morphology, timing features, and BP-estimation error; the evidence does not support quantitative ranking of classical signal-processing, statistical, and machine-learning approaches. We further identify substantial methodological inconsistency in pressure measurement, control, and reporting, and propose standardized pressure-aware practices to improve reproducibility, benchmarking, device design, and the clinical translation of cuffless BP monitoring.

Authors

Institutions

Publication Details

Journal
npj Biosensing
Published
2026-11-15
DOI
https://doi.org/10.1038/s44328-026-00120-y
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Sensor-skin contact pressure as a hidden confounder in wearable photoplethysmography biosensing

John Allen, Mohamed Elgendi, Sara Alameri, Azza Elkhalifa et al.
npj Biosensing
Non-Invasive Vital Sign Monitoring
article

Sensor-skin contact pressure as a hidden confounder in wearable photoplethysmography biosensing

John Allen, Mohamed Elgendi, Sara Alameri, Azza Elkhalifa, Shahad Alzaabi, Najoud Alhammadi, Anood Alali, Richard Ribon Fletcher
article en

Abstract

Photoplethysmography (PPG) is increasingly used for cuffless blood pressure (BP) monitoring and wearable cardiovascular sensing. However, the reliability of PPG-derived digital biomarkers is highly sensitive to sensor–skin contact pressure, which influences optical coupling, vascular compression, and motion susceptibility. Despite its importance, contact pressure is often poorly controlled or insufficiently reported, introducing a hidden source of variability that can compromise signal integrity, downstream model performance, and the reproducibility of wearable BP systems. Here, we systematically review experimental evidence on the influence of contact pressure in PPG-based cuffless BP estimation. Across 29 studies of PPG acquisition, BP estimation, and related pulse sensing, those that examined contact loading reported the following qualitative patterns: insufficient pressure reduced optical stability and increased motion artefacts, whereas excessive pressure compressed superficial vasculature, attenuated systolic peaks, and suppressed the dicrotic notch. Within studies that varied contact loading, favourable conditions depended on the anatomical site, sensor, and outcome; better waveform quality did not by itself establish lower BP-estimation error or a universal pressure target. Low, moderate, and high loading conditions are therefore used only as study-defined descriptions of signal-level effects. Because reported performance metrics represented different statistical constructs, outcomes were summarized separately for signal quality, waveform morphology, timing features, and BP-estimation error; the evidence does not support quantitative ranking of classical signal-processing, statistical, and machine-learning approaches. We further identify substantial methodological inconsistency in pressure measurement, control, and reporting, and propose standardized pressure-aware practices to improve reproducibility, benchmarking, device design, and the clinical translation of cuffless BP monitoring.

npj Biosensing
Khalifa University of Science and Technology (AE), Massachusetts Institute of Technology (US), Newcastle University (GB)
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon