Reading Hailpads Backwards: Dent Diameters Converted to Stone Energies through a Calibration Budget

This paper evaluates a hailpad records each impact as a dent whose diameter grows with the stone's kinetic energy through a calibration relation, conventionally a cubic in dent diameter; inverting that relation turns an inexpensive foam pad into an energy-resolving instrument. The case examined is a pad calibration of 0.0026 joules per cubic millimetre of dent diameter cubed, applied to dents of 6, 10, 14, 18 and 24 millimetres, with a reference stone of 30 millimetres at ice density 900 kilograms per cubic metre, air density 0.9 kilograms per cubic metre and drag coefficient 0.55 for cross-checking. The quantities produced are the energy assigned to each dent size, the ratio between the largest and smallest dent energies, the dent the reference stone should leave, and the sensitivity of the largest energy to a twenty percent calibration change. For the hailpad case, the largest dent corresponds to 35.9 joules, the smallest to 0.562 joules; reference dent 12.0 millimetres. Hailpad networks trade precision for coverage; the calibration budget states exactly what that trade costs and buys, in joules per dent.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-15
DOI
https://doi.org/10.5281/zenodo.24239811
Primary Topic
Precipitation Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Reading Hailpads Backwards: Dent Diameters Converted to Stone Energies through a Calibration Budget

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Precipitation Measurement and Analysis
article

Reading Hailpads Backwards: Dent Diameters Converted to Stone Energies through a Calibration Budget

William Alexander Aldred
article en

Abstract

This paper evaluates a hailpad records each impact as a dent whose diameter grows with the stone's kinetic energy through a calibration relation, conventionally a cubic in dent diameter; inverting that relation turns an inexpensive foam pad into an energy-resolving instrument. The case examined is a pad calibration of 0.0026 joules per cubic millimetre of dent diameter cubed, applied to dents of 6, 10, 14, 18 and 24 millimetres, with a reference stone of 30 millimetres at ice density 900 kilograms per cubic metre, air density 0.9 kilograms per cubic metre and drag coefficient 0.55 for cross-checking. The quantities produced are the energy assigned to each dent size, the ratio between the largest and smallest dent energies, the dent the reference stone should leave, and the sensitivity of the largest energy to a twenty percent calibration change. For the hailpad case, the largest dent corresponds to 35.9 joules, the smallest to 0.562 joules; reference dent 12.0 millimetres. Hailpad networks trade precision for coverage; the calibration budget states exactly what that trade costs and buys, in joules per dent.

Zenodo (CERN European Organization for Nuclear Research)
Precipitation Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Reading Hailpads Backwards: Dent Diameters Converted to Stone Energies through a Calibration Budget — William Alexander Aldred · Zenodo (CERN European Organization for Nuclear Research) (2026) | TGRS Research Map | TGRS