Multi-Shaker Sine Control: What Is Published, and Where It Stops

A sine test with several shakers is controlled, as published, through a model of the test article measured at a low level before the test. This survey collects what is published: five forms of control law with their equations checked against the page, what the test standards ask of a sine test and of several exciters, what vendors and facilities say they do, the effect of sweep rate on a lightly damped resonance, how limits and notching are handled, what active noise control, helicopter vibration control and rotor balancing know about holding a tone with several actuators, and what nonlinear vibration testing does with feedback. The published laws are thin on evidence: one two-axis table test, two beam tests, one simulation and one run-to-run time-domain method, none on a structure whose resonances move with level. No standard read sets a phase tolerance or a sine clause for several exciters. Two pieces of arithmetic of our own, shown in full, tie the sources together: the number of its own time constants a mode is given while a sweep crosses its bandwidth, which shows that a correction alone cannot hold a lightly damped mode below a few hundred hertz at the rates tests are run; and the largest phase error of a low-level model at a resonance that has moved, which reaches 90 degrees, where a one-channel correction stops converging, after a move of one half-power bandwidth. Where the published work stops is stated gap by gap, worded to a search without subscription databases. Hertzforge Journal 1, 2026-003, version 1. The version of record is the article page at https://hertzforge.com/journal/2026-003/v1/. This deposit holds that page, the article in one file (it opens without a network connection), the PDF print copy, and the bundle of the data behind every figure and the code that draws it. The article is reviewed in public after publication; its reviews, its review status and any later version are at https://hertzforge.com/journal/2026-003/.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-15
DOI
https://doi.org/10.5281/zenodo.24254056
Primary Topic
Aeroelasticity and Vibration Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Multi-Shaker Sine Control: What Is Published, and Where It Stops

Kevin Cross
Zenodo (CERN European Organization for Nuclear Research)
Aeroelasticity and Vibration Control
article

Multi-Shaker Sine Control: What Is Published, and Where It Stops

Kevin Cross
article en

Abstract

A sine test with several shakers is controlled, as published, through a model of the test article measured at a low level before the test. This survey collects what is published: five forms of control law with their equations checked against the page, what the test standards ask of a sine test and of several exciters, what vendors and facilities say they do, the effect of sweep rate on a lightly damped resonance, how limits and notching are handled, what active noise control, helicopter vibration control and rotor balancing know about holding a tone with several actuators, and what nonlinear vibration testing does with feedback. The published laws are thin on evidence: one two-axis table test, two beam tests, one simulation and one run-to-run time-domain method, none on a structure whose resonances move with level. No standard read sets a phase tolerance or a sine clause for several exciters. Two pieces of arithmetic of our own, shown in full, tie the sources together: the number of its own time constants a mode is given while a sweep crosses its bandwidth, which shows that a correction alone cannot hold a lightly damped mode below a few hundred hertz at the rates tests are run; and the largest phase error of a low-level model at a resonance that has moved, which reaches 90 degrees, where a one-channel correction stops converging, after a move of one half-power bandwidth. Where the published work stops is stated gap by gap, worded to a search without subscription databases. Hertzforge Journal 1, 2026-003, version 1. The version of record is the article page at https://hertzforge.com/journal/2026-003/v1/. This deposit holds that page, the article in one file (it opens without a network connection), the PDF print copy, and the bundle of the data behind every figure and the code that draws it. The article is reviewed in public after publication; its reviews, its review status and any later version are at https://hertzforge.com/journal/2026-003/.

Zenodo (CERN European Organization for Nuclear Research)
Aeroelasticity and Vibration Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon