Segmental aortic energy loss in patients with bicuspid aortic valve

Background Altered aortic flow dynamics are observed in patients with bicuspid aortic valve (BAV), but their local energetic characteristics remain incompletely understood. The primary objective was to compare total and segmental energy loss (EL) between patients with BAV without significant valve dysfunction and matched controls. The subsequent clinical and structural course of the BAV cohort was described. Methods Sixteen patients with BAV and 16 matched controls underwent baseline four-dimensional flow cardiovascular magnetic resonance. Total and segmental aortic EL were quantified and normalized to flow. Commissural orientation was assessed. Clinical follow-up was available in all 16 patients with BAV, and paired baseline and approximately 10-year CMR assessments of aortic dimensions were available in 14. Results Mean flow-normalized EL was approximately twofold higher in patients with BAV from the sinus of Valsalva to proximal ascending aorta (0.78 [0.59–1.14] vs 0.40 [0.29–0.67] mW/[L/min]; P = 0.015) and from proximal to distal ascending aorta (1.26 [0.79–1.59] vs 0.64 [0.39–1.07] mW/[L/min]; P = 0.013). Commissural angle was not significantly associated with segmental EL. No major BAV-related cardiovascular complications occurred during follow-up. In paired examinations, maximum ascending aortic diameter increased from 3.40 ± 0.67 to 3.75 ± 0.67 cm (P < 0.001), whereas the body surface area-indexed increase was attenuated (1.88 ± 0.29 to 1.97 ± 0.33 cm/m 2 ; P = 0.056). Conclusions Segmental aortic EL was increased in patients with BAV despite the absence of significant valve dysfunction. The approximately 10-year follow-up provides descriptive clinical and structural characterization but does not establish a relationship between baseline EL and subsequent outcomes.

Authors

Institutions

Publication Details

Journal
IJC Heart & Vasculature
Published
2026-11-15
DOI
https://doi.org/10.1016/j.ijcha.2026.102043
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Segmental aortic energy loss in patients with bicuspid aortic valve

Heiko C. Stern, Peter Ewert, Christian Meierhofer, Mikiko Harada et al.
IJC Heart & Vasculature
Aortic Disease and Treatment Approaches
article

Segmental aortic energy loss in patients with bicuspid aortic valve

Heiko C. Stern, Peter Ewert, Christian Meierhofer, Mikiko Harada, Nerejda Shehu, Maria Skarlatoudi
article en

Abstract

Background Altered aortic flow dynamics are observed in patients with bicuspid aortic valve (BAV), but their local energetic characteristics remain incompletely understood. The primary objective was to compare total and segmental energy loss (EL) between patients with BAV without significant valve dysfunction and matched controls. The subsequent clinical and structural course of the BAV cohort was described. Methods Sixteen patients with BAV and 16 matched controls underwent baseline four-dimensional flow cardiovascular magnetic resonance. Total and segmental aortic EL were quantified and normalized to flow. Commissural orientation was assessed. Clinical follow-up was available in all 16 patients with BAV, and paired baseline and approximately 10-year CMR assessments of aortic dimensions were available in 14. Results Mean flow-normalized EL was approximately twofold higher in patients with BAV from the sinus of Valsalva to proximal ascending aorta (0.78 [0.59–1.14] vs 0.40 [0.29–0.67] mW/[L/min]; P = 0.015) and from proximal to distal ascending aorta (1.26 [0.79–1.59] vs 0.64 [0.39–1.07] mW/[L/min]; P = 0.013). Commissural angle was not significantly associated with segmental EL. No major BAV-related cardiovascular complications occurred during follow-up. In paired examinations, maximum ascending aortic diameter increased from 3.40 ± 0.67 to 3.75 ± 0.67 cm (P < 0.001), whereas the body surface area-indexed increase was attenuated (1.88 ± 0.29 to 1.97 ± 0.33 cm/m 2 ; P = 0.056). Conclusions Segmental aortic EL was increased in patients with BAV despite the absence of significant valve dysfunction. The approximately 10-year follow-up provides descriptive clinical and structural characterization but does not establish a relationship between baseline EL and subsequent outcomes.

IJC Heart & VasculatureVol. 67
Shinshu University (JP), Shinshu University Hospital (JP), Deutsches Herzzentrum München (DE), Technical University of Munich (DE)
Aortic Disease and Treatment Approaches
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon