Density, Pressure and Sound Speed of Prominence Plasma from an Emission-Measure Inversion

Ultraviolet spectrographs measure an emission measure for prominence plasma near 10^28.7 per centimetre to the fifth power, while imaging gives the line-of-sight path through the sheet at a few thousand kilometres. Because emission measure is the path integral of the squared electron density, dividing by the path length and taking a square root returns the electron density itself, and that density combined with a kinetic temperature near 8,000 kelvin fixes the gas pressure, the sound speed and the pressure scale height without further assumptions. Headline values are emdiag electron density per cm3 emdiag = 10000000000; emdiag electron density SI units emdiag = 1e+16; emdiag total particle density per cm3 emdiag = 23000000000; emdiag gas pressure Pa emdiag = 0.00254; emdiag gas pressure dyn per cm2 emdiag = 0.0254; emdiag sound speed m per s emdiag = 1.343e+04. The inversion returns a pressure close to that of the surrounding million-degree corona, which is the quantitative content of the familiar statement that prominences sit in approximate pressure balance with their environment.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-15
DOI
https://doi.org/10.5281/zenodo.24260063
Primary Topic
Solar and Space Plasma Dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Density, Pressure and Sound Speed of Prominence Plasma from an Emission-Measure Inversion

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Solar and Space Plasma Dynamics
article

Density, Pressure and Sound Speed of Prominence Plasma from an Emission-Measure Inversion

William Alexander Aldred
article en

Abstract

Ultraviolet spectrographs measure an emission measure for prominence plasma near 10^28.7 per centimetre to the fifth power, while imaging gives the line-of-sight path through the sheet at a few thousand kilometres. Because emission measure is the path integral of the squared electron density, dividing by the path length and taking a square root returns the electron density itself, and that density combined with a kinetic temperature near 8,000 kelvin fixes the gas pressure, the sound speed and the pressure scale height without further assumptions. Headline values are emdiag electron density per cm3 emdiag = 10000000000; emdiag electron density SI units emdiag = 1e+16; emdiag total particle density per cm3 emdiag = 23000000000; emdiag gas pressure Pa emdiag = 0.00254; emdiag gas pressure dyn per cm2 emdiag = 0.0254; emdiag sound speed m per s emdiag = 1.343e+04. The inversion returns a pressure close to that of the surrounding million-degree corona, which is the quantitative content of the familiar statement that prominences sit in approximate pressure balance with their environment.

Zenodo (CERN European Organization for Nuclear Research)
Solar and Space Plasma Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon