Deep-learning body composition analysis of routine CT robust to scan range, slice order and contrast phase

Purpose: To develop and validate a fully automated pipeline that measures skeletal muscle and adipose tissue at L1 and L3 on routine CT with varied scan ranges, slice orders and contrast phases, rejects levels outside the scan and converts measures to non-contrast equivalents. Materials and methods: The pipeline (sarco) combines orientation detection, L1/L3 localisation with out-of-range rejection, U-Net segmentation, six-class contrast-phase estimation, phase-specific conversion to non-contrast-equivalent values and, as an auxiliary output, muscle and marrow age estimation. We evaluated it on five single-centre datasets (4986 series): agreement with radiologist-corrected labels using five-fold cross-fitting (2025 series), artificially truncated scans, contrast-enhanced series paired with non-contrast series of the same examination, and the prognostic value of fully automated measures in 2006 patients after curative cancer surgery. TotalSegmentator served as a comparator. Results: On held-out folds, L3 skeletal muscle area (SMA) agreed with the reference (intraclass correlation coefficient 0.983; bias +1.35 cm2). On truncated scans processed with cross-fitted localisation models, the chosen L3 slice was off by half a vertebra or more in 4.7-5.6% of volumes (TotalSegmentator 11.3-14.3%). Four-group phase accuracy was 0.949, exceeding TotalSegmentator in scans shorter than 400 mm (0.952-0.960 vs 0.643-0.668), and conversion reduced the root mean square error of L3 muscle attenuation against the same-examination non-contrast series from 7.96 to 2.81 HU. Combined age estimates had a mean absolute error of 6.5 years. Automatically measured low muscle mass increased the cross-validated Uno's C of the baseline model by 0.034 (95% CI 0.009-0.053; cancer-specific survival) and 0.031 (0.016-0.048; overall survival), whereas converted L3 muscle attenuation added 0.012 (-0.005 to 0.024) for overall survival. Conclusion: The pipeline provides robust, contrast-phase-aware body composition measures from routine CT with varied scan ranges and reproduces known prognostic associations without manual input.

Authors

Institutions

Publication Details

Journal
medRxiv
Published
2026-11-15
DOI
https://doi.org/10.64898/2026.11.12.26367971
Primary Topic
Medical Image Segmentation Techniques
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Deep-learning body composition analysis of routine CT robust to scan range, slice order and contrast phase

Taketo Kawai, Haruki Kume, Nobuhiko Akamatsu, Tomomi Takenaga et al.
medRxiv
Medical Image Segmentation Techniques
preprint

Deep-learning body composition analysis of routine CT robust to scan range, slice order and contrast phase

Taketo Kawai, Haruki Kume, Nobuhiko Akamatsu, Tomomi Takenaga, Osamu Abe, Kotaro Sugawara, Soichiro Miki, Shohei Inui, Satoru Taguchi, Kenjiro Kishitani, T. Yoshikawa, Wataru Gonoi, Shouhei Hanaoka, Yukihiro Nomura, Tohru Nakagawa
preprint en

Abstract

Purpose: To develop and validate a fully automated pipeline that measures skeletal muscle and adipose tissue at L1 and L3 on routine CT with varied scan ranges, slice orders and contrast phases, rejects levels outside the scan and converts measures to non-contrast equivalents. Materials and methods: The pipeline (sarco) combines orientation detection, L1/L3 localisation with out-of-range rejection, U-Net segmentation, six-class contrast-phase estimation, phase-specific conversion to non-contrast-equivalent values and, as an auxiliary output, muscle and marrow age estimation. We evaluated it on five single-centre datasets (4986 series): agreement with radiologist-corrected labels using five-fold cross-fitting (2025 series), artificially truncated scans, contrast-enhanced series paired with non-contrast series of the same examination, and the prognostic value of fully automated measures in 2006 patients after curative cancer surgery. TotalSegmentator served as a comparator. Results: On held-out folds, L3 skeletal muscle area (SMA) agreed with the reference (intraclass correlation coefficient 0.983; bias +1.35 cm2). On truncated scans processed with cross-fitted localisation models, the chosen L3 slice was off by half a vertebra or more in 4.7-5.6% of volumes (TotalSegmentator 11.3-14.3%). Four-group phase accuracy was 0.949, exceeding TotalSegmentator in scans shorter than 400 mm (0.952-0.960 vs 0.643-0.668), and conversion reduced the root mean square error of L3 muscle attenuation against the same-examination non-contrast series from 7.96 to 2.81 HU. Combined age estimates had a mean absolute error of 6.5 years. Automatically measured low muscle mass increased the cross-validated Uno's C of the baseline model by 0.034 (95% CI 0.009-0.053; cancer-specific survival) and 0.031 (0.016-0.048; overall survival), whereas converted L3 muscle attenuation added 0.012 (-0.005 to 0.024) for overall survival. Conclusion: The pipeline provides robust, contrast-phase-aware body composition measures from routine CT with varied scan ranges and reproduces known prognostic associations without manual input.

medRxiv
Chiba University (JP), National Center for Global Health and Medicine (JP), University of Tokyo Hospital (JP), Nerima Hikarigaoka Hospital (JP), Japan Institute for Health Security (JP), Center for Frontier Medical Engineering, Chiba University (JP), The University of Tokyo (JP), Teikyo University (JP)
Medical Image Segmentation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon