A Single-Station On-Site P-Wave Warning Unit for an Industrial Facility: Threshold, Decision Window and Shut-Down Budgets

One rugged three-component sensor in a plant's utility yard watches its own ground motion, estimates from the first three seconds of the P wave whether the coming S shaking will exceed the plant's damage threshold, and trips valves, burners and cranes without waiting for any regional network. Its operating principle: a lone on-site sensor that reads the opening seconds of its own P wave and acts before the S wave reaches the same building. Headline values are onsite p travel onsite to nearest station onsite s = 8.57; onsite detection latency onsite s = 11.62; onsite total alert onsite latency s = 12.82; onsite blind zone onsite radius km = 43.24; onsite warning time onsite at 50 km onsite s = 1.871; onsite warning time onsite at 100 km onsite s = 15.96. With one sensor there is no voting geometry to report; the entries instead expose the threshold trade between acting early and acting wrongly. SIMULATED, NOT MEASURED. Computed for the protection of workers and neighbours at one industrial site, this study is not a targeting device and carries no weapon application against any individual, government or earthly object.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-16
DOI
https://doi.org/10.5281/zenodo.24265414
Primary Topic
Seismology and Earthquake Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Single-Station On-Site P-Wave Warning Unit for an Industrial Facility: Threshold, Decision Window and Shut-Down Budgets

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Seismology and Earthquake Studies
article

A Single-Station On-Site P-Wave Warning Unit for an Industrial Facility: Threshold, Decision Window and Shut-Down Budgets

William Alexander Aldred
article en

Abstract

One rugged three-component sensor in a plant's utility yard watches its own ground motion, estimates from the first three seconds of the P wave whether the coming S shaking will exceed the plant's damage threshold, and trips valves, burners and cranes without waiting for any regional network. Its operating principle: a lone on-site sensor that reads the opening seconds of its own P wave and acts before the S wave reaches the same building. Headline values are onsite p travel onsite to nearest station onsite s = 8.57; onsite detection latency onsite s = 11.62; onsite total alert onsite latency s = 12.82; onsite blind zone onsite radius km = 43.24; onsite warning time onsite at 50 km onsite s = 1.871; onsite warning time onsite at 100 km onsite s = 15.96. With one sensor there is no voting geometry to report; the entries instead expose the threshold trade between acting early and acting wrongly. SIMULATED, NOT MEASURED. Computed for the protection of workers and neighbours at one industrial site, this study is not a targeting device and carries no weapon application against any individual, government or earthly object.

Zenodo (CERN European Organization for Nuclear Research)
Seismology and Earthquake Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon