Design Blueprint: High-Altitude Balloon-Borne Wind Turbine: Shear-Profile Gain, Altitude Density and Buoyancy Budgets

Design blueprint derived from the source paper (DOI 10.5281/zenodo.24239626): This paper presents a computed balloon-borne turbine design, rated at 8.72 kilowatts, on a single stated operating principle: a helium aerostat carries a shrouded rotor to several hundred metres, where the wind is stronger and steadier than at any tower height; power returns down the tether, and the budget balances the altitude wind gain against the density loss and the balloon's lift requirement. The system studied is a rotor 7 metres in diameter held at 350 metres by an aerostat 18 metres in diameter, with surface wind 6 metres per second, shear exponent 0.16, and rotor power coefficient 0.40 at the computed altitude density. The target quantity is net electrical output from the computed altitude wind speed by the power-law profile, the altitude air density by the exponential atmosphere, and the standard rotor chain, with balloon gross lift printed as the configuration's feasibility check. For the balloon-borne turbine, the net output is 8.72 kilowatts, and the annual yield is 32.1 megawatt-hours, at a capacity factor of 0.42. Wind speed at operating altitude is 10.6 metres per second. Air density at altitude is 1.18 kilograms per cubic metre. Stream power at altitude is 26.9 kilowatts. Aerostat gross lift is 31.7 kilonewtons. The study is a civilian energy design throughout, with no targeting or weapon application, and its results are simulated, not measured. Status: DESIGN BLUEPRINT — SIMULATED, NOT MEASURED — NOT BUILT. All numbers are simulated values from the source paper's computation, deposited with this blueprint as compute.py and results.json. The design is a civilian wind energy system and has no targeting or weapon application. AI-use disclosure: Dave, an AI research system, assisted with the computation and drafting under the author's direction; author of record William Alexander Aldred.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-15
DOI
https://doi.org/10.5281/zenodo.24241801
Primary Topic
Aerospace Engineering and Energy Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Design Blueprint: High-Altitude Balloon-Borne Wind Turbine: Shear-Profile Gain, Altitude Density and Buoyancy Budgets

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Aerospace Engineering and Energy Systems
article

Design Blueprint: High-Altitude Balloon-Borne Wind Turbine: Shear-Profile Gain, Altitude Density and Buoyancy Budgets

William Alexander Aldred
article en

Abstract

Design blueprint derived from the source paper (DOI 10.5281/zenodo.24239626): This paper presents a computed balloon-borne turbine design, rated at 8.72 kilowatts, on a single stated operating principle: a helium aerostat carries a shrouded rotor to several hundred metres, where the wind is stronger and steadier than at any tower height; power returns down the tether, and the budget balances the altitude wind gain against the density loss and the balloon's lift requirement. The system studied is a rotor 7 metres in diameter held at 350 metres by an aerostat 18 metres in diameter, with surface wind 6 metres per second, shear exponent 0.16, and rotor power coefficient 0.40 at the computed altitude density. The target quantity is net electrical output from the computed altitude wind speed by the power-law profile, the altitude air density by the exponential atmosphere, and the standard rotor chain, with balloon gross lift printed as the configuration's feasibility check. For the balloon-borne turbine, the net output is 8.72 kilowatts, and the annual yield is 32.1 megawatt-hours, at a capacity factor of 0.42. Wind speed at operating altitude is 10.6 metres per second. Air density at altitude is 1.18 kilograms per cubic metre. Stream power at altitude is 26.9 kilowatts. Aerostat gross lift is 31.7 kilonewtons. The study is a civilian energy design throughout, with no targeting or weapon application, and its results are simulated, not measured. Status: DESIGN BLUEPRINT — SIMULATED, NOT MEASURED — NOT BUILT. All numbers are simulated values from the source paper's computation, deposited with this blueprint as compute.py and results.json. The design is a civilian wind energy system and has no targeting or weapon application. AI-use disclosure: Dave, an AI research system, assisted with the computation and drafting under the author's direction; author of record William Alexander Aldred.

Zenodo (CERN European Organization for Nuclear Research)
Aerospace Engineering and Energy Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon