Yttrium Iron Garnet: Gilbert Damping, Frequency-Dependent Linewidth, Magnon Lifetime and Resonance Quality

Yttrium iron garnet owes its central place in magnonics to a Gilbert damping parameter that can fall to the 10^-4 range in films and lower in polished spheres, giving resonance linewidths under one oersted and magnon lifetimes of hundreds of nanoseconds at microwave frequencies. Gilbert damping makes the field-swept linewidth grow linearly with frequency, with slope set by twice the damping parameter divided by the gyromagnetic ratio, on top of a frequency-independent inhomogeneous offset; the same parameter fixes the magnon lifetime as the inverse of damping times angular frequency and the resonance quality factor as its reciprocal combination. Headline values are gilbert linewidth at 10ghz mt garnet = 0.09143; gilbert linewidth at 10ghz oe garnet = 0.9143; gilbert frequency linewidth at 10ghz mhz garnet = 2; gilbert magnon lifetime at 10ghz ns garnet = 159.2; gilbert quality factor at 10ghz garnet = 5000; gilbert linewidth at 2ghz mt garnet = 0.03429. Slope and intercept are quoted separately, because they indict different culprits, growth quality in one case and uniformity in the other.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-16
DOI
https://doi.org/10.5281/zenodo.24264944
Primary Topic
Magnetic properties of thin films
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Yttrium Iron Garnet: Gilbert Damping, Frequency-Dependent Linewidth, Magnon Lifetime and Resonance Quality

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Magnetic properties of thin films
article

Yttrium Iron Garnet: Gilbert Damping, Frequency-Dependent Linewidth, Magnon Lifetime and Resonance Quality

William Alexander Aldred
article en

Abstract

Yttrium iron garnet owes its central place in magnonics to a Gilbert damping parameter that can fall to the 10^-4 range in films and lower in polished spheres, giving resonance linewidths under one oersted and magnon lifetimes of hundreds of nanoseconds at microwave frequencies. Gilbert damping makes the field-swept linewidth grow linearly with frequency, with slope set by twice the damping parameter divided by the gyromagnetic ratio, on top of a frequency-independent inhomogeneous offset; the same parameter fixes the magnon lifetime as the inverse of damping times angular frequency and the resonance quality factor as its reciprocal combination. Headline values are gilbert linewidth at 10ghz mt garnet = 0.09143; gilbert linewidth at 10ghz oe garnet = 0.9143; gilbert frequency linewidth at 10ghz mhz garnet = 2; gilbert magnon lifetime at 10ghz ns garnet = 159.2; gilbert quality factor at 10ghz garnet = 5000; gilbert linewidth at 2ghz mt garnet = 0.03429. Slope and intercept are quoted separately, because they indict different culprits, growth quality in one case and uniformity in the other.

Zenodo (CERN European Organization for Nuclear Research)
Magnetic properties of thin films
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon