Shanghai Synchrotron Radiation Facility: Radiated Power and Absorber Heat-Load Budgets at 3.5 GeV
This paper recomputes the principal source budgets of Shanghai Synchrotron Radiation Facility from its published headline parameters: a beam energy of 3.5 GeV, a stored current of 0.3 A, a circumference of 432.0 m and a dipole field of 1.27 T. The bending radius implied by those inputs is 9.19 m, giving a critical energy of 10.35 keV against a published value of 10.4 keV, an energy loss per turn of 1444 keV and a total radiated power of 433 kW against 430.0 kW published. A reference undulator of 2.7 cm period and 0.85 T peak field has parameter K of 2.14 and a fundamental at 1.31 keV, with the third and fifth harmonics reaching 3.9 keV and 6.5 keV. At the reference wavelength of 10.0 nm the diffraction-limited emittance is 795.8 pm rad, so the stored beam, with a horizontal emittance of 3900.0 pm rad, carries a coherent fraction of about 0.204. Computed and published values agree at the level expected once lattice averages and insertion-device loads are accounted for, which makes the published parameter set an internally consistent basis for planning experiments at this facility.
Authors
- William Alexander Aldred (ORCID: https://orcid.org/0009-0000-1215-577X)
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-15
- DOI
- https://doi.org/10.5281/zenodo.24242841
- Primary Topic
- Particle Accelerators and Free-Electron Lasers
- Type
- article
- Field-Weighted Citation Impact
- 0.00