MAX IV: Multibend Achromat Emittance and Diffraction-Limited Operation at 3 GeV
This paper recomputes the principal source budgets of MAX IV Laboratory from its published headline parameters: a beam energy of 3.0 GeV, a stored current of 0.5 A, a circumference of 528.0 m and a dipole field of 0.92 T. The bending radius implied by those inputs is 10.88 m, giving a critical energy of 5.51 keV against a published value of 5.5 keV, an energy loss per turn of 659 keV and a total radiated power of 329 kW against 330.0 kW published. A reference undulator of 1.9 cm period and 0.85 T peak field has parameter K of 1.51 and a fundamental at 2.11 keV, with the third and fifth harmonics reaching 6.3 keV and 10.5 keV. At the reference wavelength of 2.0 nm the diffraction-limited emittance is 159.2 pm rad, so the stored beam, with a horizontal emittance of 328.0 pm rad, carries a coherent fraction of about 0.485. Computed and published values agree at the level expected once lattice averages and insertion-device loads are accounted for, which makes the published parameter set an internally consistent basis for planning experiments at this facility.
Authors
- William Alexander Aldred (ORCID: https://orcid.org/0009-0000-1215-577X)
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-15
- DOI
- https://doi.org/10.5281/zenodo.24242727
- Primary Topic
- Particle Accelerators and Free-Electron Lasers
- Type
- article
- Field-Weighted Citation Impact
- 0.00