Influence of different periodontal ligament simulation materials and thicknesses on the fracture resistance of endodontically treated teeth: an in vitro study

Periodontal ligament (PDL) simulation is widely used in mechanical laboratory studies, but whether variation in the simulation material and spacer thickness materially affects fracture outcomes remains uncertain. This study evaluated these methodological variables in root canal-treated teeth. One hundred five decoronated single-rooted teeth (root length 16 mm) were instrumented (ProTaper Gold) and obturated with gutta-percha/resin-based root canal sealer. Standardized PDL spaces (0.25, 0.50, 1.25 mm) were created using calibrated medical tape; spaces were filled with condensation silicone (CS) or polyether (PE) (2 × 3 design; n = 15/group). Controls ( n = 15) were embedded without PDL simulation. Specimens underwent vertical compressive loading (1 mm/min) until fracture; maximum load (N) was recorded, and fractures were classified as repairable or non-repairable. Data were analyzed using one-way ANOVA, secondary 2 × 3 factorial ANOVA, Dunnett tests versus control, and the Fisher–Freeman–Halton exact test for fracture reparability outcomes (α = 0.05). No significant main effects of PDL-simulating material or spacer thickness and no material × thickness interaction were detected. The control group had a numerically higher mean fracture load, although the overall between-group effect was not statistically significant ( p > 0.05). Repairable/non-repairable fracture distribution was similar among groups (exact p = 0.196). Under the conditions of this static in vitro model, the tested variations in PDL-simulating elastomer and spacer thickness did not produce large or statistically detectable changes in fracture resistance or fracture reparability. These findings are methodologically informative but do not establish equivalence among the tested conditions or superiority of the tape-based spacer approach.

Authors

Institutions

Publication Details

Journal
BMC Oral Health
Published
2026-11-16
DOI
https://doi.org/10.1186/s12903-026-10376-5
Primary Topic
Endodontics and Root Canal Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Influence of different periodontal ligament simulation materials and thicknesses on the fracture resistance of endodontically treated teeth: an in vitro study

Özgür Uyanık, Emel Özyürek, Şevval Sarıoğlu
3 links
BMC Oral Health
Endodontics and Root Canal Treatments
article

Influence of different periodontal ligament simulation materials and thicknesses on the fracture resistance of endodontically treated teeth: an in vitro study

Özgür Uyanık, Emel Özyürek, Şevval Sarıoğlu
article en

Abstract

Periodontal ligament (PDL) simulation is widely used in mechanical laboratory studies, but whether variation in the simulation material and spacer thickness materially affects fracture outcomes remains uncertain. This study evaluated these methodological variables in root canal-treated teeth. One hundred five decoronated single-rooted teeth (root length 16 mm) were instrumented (ProTaper Gold) and obturated with gutta-percha/resin-based root canal sealer. Standardized PDL spaces (0.25, 0.50, 1.25 mm) were created using calibrated medical tape; spaces were filled with condensation silicone (CS) or polyether (PE) (2 × 3 design; n = 15/group). Controls ( n = 15) were embedded without PDL simulation. Specimens underwent vertical compressive loading (1 mm/min) until fracture; maximum load (N) was recorded, and fractures were classified as repairable or non-repairable. Data were analyzed using one-way ANOVA, secondary 2 × 3 factorial ANOVA, Dunnett tests versus control, and the Fisher–Freeman–Halton exact test for fracture reparability outcomes (α = 0.05). No significant main effects of PDL-simulating material or spacer thickness and no material × thickness interaction were detected. The control group had a numerically higher mean fracture load, although the overall between-group effect was not statistically significant ( p > 0.05). Repairable/non-repairable fracture distribution was similar among groups (exact p = 0.196). Under the conditions of this static in vitro model, the tested variations in PDL-simulating elastomer and spacer thickness did not produce large or statistically detectable changes in fracture resistance or fracture reparability. These findings are methodologically informative but do not establish equivalence among the tested conditions or superiority of the tape-based spacer approach.

BMC Oral Health
Hacettepe University (TR)
Good health and well-being
Endodontics and Root Canal Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon