Design Blueprint: Pneumatic Chamber Array Power: Shared-Manifold Air Turbines, Per-Chamber Capture and Array-Interaction Budgets

Design blueprint derived from the source paper (DOI 10.5281/zenodo.24238462): The chamber array is presented here: a computed chamber array design, rated at 726 kilowatts, on the chamber array's single stated chamber array operating principle: a row of water-column chambers along a breakwater or reef crest shares one air manifold and one set of turbines; the chambers fire out of phase as the wave travels along the row, so the manifold smooths the pulsating air flow that a single chamber delivers in gusts — the array itself is the operating principle. The chamber array system is twenty-four chambers each 6 metres wide in waters of significant wave height 2.3 metres and energy period 8.0 seconds, with per-chamber capture width, a stated array interaction factor and a shared Wells-turbine efficiency. The chamber array's target is the chamber array net electrical output using the computed per-chamber pneumatic power summed over the array at the stated interaction factor, with manifold pressure printed because the shared duct, not any chamber, sets the turbines' working point. For the chamber array, the net output is 726 kilowatts, and the chamber array's annual yield is 1.72 gigawatt-hours, at the chamber array's capacity factor of 0.27. Per-chamber pneumatic power is 54.8 kilowatts before the array factor, and manifold pressure is about 12.7 kilopascals. Civilian energy supply is the sole purpose examined; the paper is a computed simulation from stated assumptions, not a measurement, and no targeting or weapon application is involved. Status: DESIGN BLUEPRINT — SIMULATED, NOT MEASURED — NOT BUILT. All numbers are simulated values from the source paper's computation, deposited with this blueprint as compute.py and results.json. The design is a civilian wave and tidal energy system and has no targeting or weapon application. AI-use disclosure: Dave, an AI research system, assisted with the computation and drafting under the author's direction; author of record William Alexander Aldred.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-15
DOI
https://doi.org/10.5281/zenodo.24238821
Primary Topic
Wave and Wind Energy Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Design Blueprint: Pneumatic Chamber Array Power: Shared-Manifold Air Turbines, Per-Chamber Capture and Array-Interaction Budgets

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Wave and Wind Energy Systems
article

Design Blueprint: Pneumatic Chamber Array Power: Shared-Manifold Air Turbines, Per-Chamber Capture and Array-Interaction Budgets

William Alexander Aldred
article en

Abstract

Design blueprint derived from the source paper (DOI 10.5281/zenodo.24238462): The chamber array is presented here: a computed chamber array design, rated at 726 kilowatts, on the chamber array's single stated chamber array operating principle: a row of water-column chambers along a breakwater or reef crest shares one air manifold and one set of turbines; the chambers fire out of phase as the wave travels along the row, so the manifold smooths the pulsating air flow that a single chamber delivers in gusts — the array itself is the operating principle. The chamber array system is twenty-four chambers each 6 metres wide in waters of significant wave height 2.3 metres and energy period 8.0 seconds, with per-chamber capture width, a stated array interaction factor and a shared Wells-turbine efficiency. The chamber array's target is the chamber array net electrical output using the computed per-chamber pneumatic power summed over the array at the stated interaction factor, with manifold pressure printed because the shared duct, not any chamber, sets the turbines' working point. For the chamber array, the net output is 726 kilowatts, and the chamber array's annual yield is 1.72 gigawatt-hours, at the chamber array's capacity factor of 0.27. Per-chamber pneumatic power is 54.8 kilowatts before the array factor, and manifold pressure is about 12.7 kilopascals. Civilian energy supply is the sole purpose examined; the paper is a computed simulation from stated assumptions, not a measurement, and no targeting or weapon application is involved. Status: DESIGN BLUEPRINT — SIMULATED, NOT MEASURED — NOT BUILT. All numbers are simulated values from the source paper's computation, deposited with this blueprint as compute.py and results.json. The design is a civilian wave and tidal energy system and has no targeting or weapon application. AI-use disclosure: Dave, an AI research system, assisted with the computation and drafting under the author's direction; author of record William Alexander Aldred.

Zenodo (CERN European Organization for Nuclear Research)
Wave and Wind Energy Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon