A Passive Phase-Change Sample Vault Sized by Latent Storage, Heat Leak and Unpowered-Hold Budgets

Presented here is a calculated design for an insulated sample vault whose walls embed a phase-change material that melts and freezes to hold the interior temperature nearly constant without power, built on the following operating principle: heat leaking into the vault is absorbed as latent heat by a melting solid at a fixed transition temperature, and heat leaking out is returned as the material freezes, so the interior rides through unpowered intervals at the transition temperature with no machinery at all. The Latent Vault vault stores 1.1 megajoules of latent capacity, buffering 47.3 hours of unpowered hold against a required 11 hours, and each dark interval of 11 hours melts only 23 percent of its charge. Not every hour of a sample's journey offers electrical power, and the hours that do not — eclipse, entry, a recovery delayed by weather — are exactly the hours a temperature record can be lost; a phase-change vault covers those hours with physics instead of machinery. Sizing follows from calculated latent-storage, heat-leak and unpowered-hold accounts, each carried out in the deposited calculation script from stated assumptions. The study is a calculated one with a civilian planetary-science purpose and no targeting or weapon use against any person, state or earthly body. SIMULATED, NOT MEASURED.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-15
DOI
https://doi.org/10.5281/zenodo.24261223
Primary Topic
Phase Change Materials Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Passive Phase-Change Sample Vault Sized by Latent Storage, Heat Leak and Unpowered-Hold Budgets

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Phase Change Materials Research
article

A Passive Phase-Change Sample Vault Sized by Latent Storage, Heat Leak and Unpowered-Hold Budgets

William Alexander Aldred
article en

Abstract

Presented here is a calculated design for an insulated sample vault whose walls embed a phase-change material that melts and freezes to hold the interior temperature nearly constant without power, built on the following operating principle: heat leaking into the vault is absorbed as latent heat by a melting solid at a fixed transition temperature, and heat leaking out is returned as the material freezes, so the interior rides through unpowered intervals at the transition temperature with no machinery at all. The Latent Vault vault stores 1.1 megajoules of latent capacity, buffering 47.3 hours of unpowered hold against a required 11 hours, and each dark interval of 11 hours melts only 23 percent of its charge. Not every hour of a sample's journey offers electrical power, and the hours that do not — eclipse, entry, a recovery delayed by weather — are exactly the hours a temperature record can be lost; a phase-change vault covers those hours with physics instead of machinery. Sizing follows from calculated latent-storage, heat-leak and unpowered-hold accounts, each carried out in the deposited calculation script from stated assumptions. The study is a calculated one with a civilian planetary-science purpose and no targeting or weapon use against any person, state or earthly body. SIMULATED, NOT MEASURED.

Zenodo (CERN European Organization for Nuclear Research)
Phase Change Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon