Research and Engineering Implementation of Motion Physical-Quantity Feedback-Based Speed Compensation Control Technology for Precision Liquid Delivery in IVD Medical Equipment

Precision liquid delivery is a critical capability in In Vitro Diagnostics (IVD) medical equipment, essential for sample dispensing, reagent distribution, and microfluidic driving. However, periodic fluctuations, repeatability errors, and nonuniform advancement during liquid delivery severely compromise dispensing accuracy and test consistency. Conventional continuous speed control and standard closed-loop systems struggle to effectively compensate for mechanical structural errors, lead-screw periodic errors, motor microstepping inaccuracies, and fluidic-load disturbances. To overcome these challenges, this paper proposes a novel motion physical-quantity feedback-based speed compensation control method for precision liquid delivery mechanisms. The proposed approach divides the motor-driving process into discrete motion units, assigning independent speed parameters to form a dynamically correctable execution sequence. During operation, actual motion results are acquired via physical quantities such as encoder period, flow rate, pressure, and displacement. Compensation coefficients are calculated from target deviations to correct subsequent motion units. Furthermore, multi-cycle learning is employed for highly repeatable systematic errors to generate a stable speed compensation table. Experimental validation using an IVD precision syringe pump system demonstrates significant reductions in encoder-disk periodic fluctuation and liquid-output nonuniformity. Following compensation, the coefficient of variation (CV) decreased from approximately 0.6% to 0.05%, representing a tenfold improvement in system stability. Ultimately, this method offers low implementation complexity, robust engineering adaptability, and embedded deployability, providing a highly stable, practically implementable motion-control solution for precision dispensing and multi-channel liquid control in modern IVD medical equipment.

Authors

Publication Details

Journal
International Journal of Engineering Advances
Published
2026-11-16
DOI
https://doi.org/10.71222/vztkkk27
Primary Topic
Control Systems in Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Research and Engineering Implementation of Motion Physical-Quantity Feedback-Based Speed Compensation Control Technology for Precision Liquid Delivery in IVD Medical Equipment

Yanfeng He
International Journal of Engineering Advances
Control Systems in Engineering
article

Research and Engineering Implementation of Motion Physical-Quantity Feedback-Based Speed Compensation Control Technology for Precision Liquid Delivery in IVD Medical Equipment

Yanfeng He
article en

Abstract

Precision liquid delivery is a critical capability in In Vitro Diagnostics (IVD) medical equipment, essential for sample dispensing, reagent distribution, and microfluidic driving. However, periodic fluctuations, repeatability errors, and nonuniform advancement during liquid delivery severely compromise dispensing accuracy and test consistency. Conventional continuous speed control and standard closed-loop systems struggle to effectively compensate for mechanical structural errors, lead-screw periodic errors, motor microstepping inaccuracies, and fluidic-load disturbances. To overcome these challenges, this paper proposes a novel motion physical-quantity feedback-based speed compensation control method for precision liquid delivery mechanisms. The proposed approach divides the motor-driving process into discrete motion units, assigning independent speed parameters to form a dynamically correctable execution sequence. During operation, actual motion results are acquired via physical quantities such as encoder period, flow rate, pressure, and displacement. Compensation coefficients are calculated from target deviations to correct subsequent motion units. Furthermore, multi-cycle learning is employed for highly repeatable systematic errors to generate a stable speed compensation table. Experimental validation using an IVD precision syringe pump system demonstrates significant reductions in encoder-disk periodic fluctuation and liquid-output nonuniformity. Following compensation, the coefficient of variation (CV) decreased from approximately 0.6% to 0.05%, representing a tenfold improvement in system stability. Ultimately, this method offers low implementation complexity, robust engineering adaptability, and embedded deployability, providing a highly stable, practically implementable motion-control solution for precision dispensing and multi-channel liquid control in modern IVD medical equipment.

International Journal of Engineering AdvancesVol. 3(2)
Control Systems in Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon