A Cryogenic Cold-Chain Sample Return System Sized by Heat Leak, Cryocooler Power and Radiator Budgets
Shown here is a calculated design for an actively refrigerated return capsule that holds volatile-bearing samples at cryogenic temperature from collection to laboratory, operating on the declared principle: a mechanical cryocooler removes the parasitic heat leaking into an insulated sample vault and rejects it through a radiator, holding the sample far below the temperature at which its volatile inventory would redistribute or escape. Holding 90 kelvin against a 2.40 watt leak, the Cold Chain cooler draws 30 watts of its 210 watt allocation, rejects its heat through 0.06 square metres of radiator, and its stored cryogen alone would hold the cold for 14 days. Some of a returned sample's most perishable evidence is its volatile inventory, which warmth rearranges long before it destroys; a cold chain is therefore an analytical instrument in its own right, and its budget is a heat-leak budget fought watt by watt. Sizing follows from computed heat-leak, cryocooler-power and radiator accounts, each performed in the filed calculation script from stated parameters. This is a computed analysis with a civilian planetary-science purpose, with no targeting or weapon use against any individual, state or terrestrial body. SIMULATED, NOT MEASURED.