A Bio-Isolated Ground Receiving Vault Sized by Airflow, Pressure-Cascade and Inflow-Velocity Budgets

Shown here is a calculated design for a sealed receiving vault in the ground facility where the returned capsule is opened inside a negative-pressure, filtered, sterilisable enclosure, whose operating principle is this: the capsule is opened only inside a vault held below room pressure through a cascade of decreasing-pressure zones, with all exhaust passing high-efficiency filtration, so any particle released at opening travels inward with the airflow and out only through the filters. Across its transfer opening the Receiving Vault vault sustains an inflow of 0.69 metres per second against a 0.5 requirement, exchanges 14 vault volumes per hour, and holds a 45 pascal cascade between its outermost zone and the room. The receiving vault is where containment changes from a spacecraft problem into a building problem, and buildings are sized in air changes, pressure cascades and face velocities; this study works those numbers for the room where the capsule is actually opened. Sizing follows from computed airflow, pressure-cascade and inflow-velocity accounts, each worked in the deposited calculation code from specified assumptions. It is a calculated analysis with a civilian planetary-science purpose, and it carries no targeting or weapon application against any person, state or earthly body. SIMULATED, NOT MEASURED.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-15
DOI
https://doi.org/10.5281/zenodo.24260984
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Bio-Isolated Ground Receiving Vault Sized by Airflow, Pressure-Cascade and Inflow-Velocity Budgets

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Indoor Air Quality and Microbial Exposure
article

A Bio-Isolated Ground Receiving Vault Sized by Airflow, Pressure-Cascade and Inflow-Velocity Budgets

William Alexander Aldred
article en

Abstract

Shown here is a calculated design for a sealed receiving vault in the ground facility where the returned capsule is opened inside a negative-pressure, filtered, sterilisable enclosure, whose operating principle is this: the capsule is opened only inside a vault held below room pressure through a cascade of decreasing-pressure zones, with all exhaust passing high-efficiency filtration, so any particle released at opening travels inward with the airflow and out only through the filters. Across its transfer opening the Receiving Vault vault sustains an inflow of 0.69 metres per second against a 0.5 requirement, exchanges 14 vault volumes per hour, and holds a 45 pascal cascade between its outermost zone and the room. The receiving vault is where containment changes from a spacecraft problem into a building problem, and buildings are sized in air changes, pressure cascades and face velocities; this study works those numbers for the room where the capsule is actually opened. Sizing follows from computed airflow, pressure-cascade and inflow-velocity accounts, each worked in the deposited calculation code from specified assumptions. It is a calculated analysis with a civilian planetary-science purpose, and it carries no targeting or weapon application against any person, state or earthly body. SIMULATED, NOT MEASURED.

Zenodo (CERN European Organization for Nuclear Research)
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.