Flow-Rate-Dependent Thermal Performance of a Counter-Flow Double-Pipe Heat Exchanger: Energy-Balance Assessment, Effectiveness Analysis and Statistical Mapping
This study presents an experimental multi-variable performance mapping of a water-to-water counter-flow double-pipe heat exchanger conducted in the Thermo Laboratory of the Department of Mechanical Engineering, Igbinedion University Okada. Twenty steady-state operating conditions were examined in which hot-water flow rate ranged from 1.52 to 4.43 L min⁻¹ and cold-water flow rate from 3.12 to 7.02 L min⁻¹. The exchanger comprises a copper inner tube (outer diameter 25.4 mm), effective length 1.50 m and heat-transfer area 0.120 m² based on the outer surface of the inner tube. Measured heat-transfer rates increased from approximately 1.55 kW to 9.40 kW. The overall heat-transfer coefficient rose from 440 to 5144 W m⁻² K⁻¹ while the logarithmic mean temperature difference declined from 29.3 °C to 15.2 °C. Thermal effectiveness increased from 36.2 % to 74.7 %. Linear regression analyses revealed strong positive associations between hot-water flow rate and both average heat duty (R² = 0.997) and overall heat-transfer coefficient (R² = 0.978). The maximum hot/cold energy-balance discrepancy was 0.65 %. Because both stream flow rates varied simultaneously, the results constitute a multi-variable operating map rather than an isolated single-variable effect study. The work provides a transparent, statistically characterised laboratory baseline that can support teaching, equipment commissioning and preliminary design calculations.
Authors
- Lucky Olatunde ODEJIMI
- Olorunleke Aregbe
- Emeke Achojakimoni Okotie
Institutions
- Igbinedion University (NG)
Publication Details
- Journal
- IPS Journal of Physical Sciences
- Published
- 2026-11-14
- DOI
- https://doi.org/10.54117/ijps.v3i2.47
- Primary Topic
- Heat Transfer and Optimization
- Type
- article
- Field-Weighted Citation Impact
- 0.00