Experiences Using a 1.7 mm Locking Bone Plate System for Stabilization of Appendicular Fractures in Dogs and Cats

Abstract To retrospectively evaluate the stabilization of appendicular fractures using the Fixin 1.7 mm locking plate system in dogs and cats. A review of patient medical records with traumatic appendicular fractures stabilized with the Fixin 1.7 mm locking plate was performed. Fractures were excluded due to lack of follow-up radiographs, prophylactic plating, or the use of additional plates. Data pertaining to the signalment, fracture classification, implants, evidence of radiographic healing, and limb function were recorded. Stabilization included both minimally invasive plate osteosynthesis (MIPO) and open reduction and internal fixation (ORIF) methods. Outcomes were determined from clinical and radiographic follow-ups. One hundred out of 133 evaluated fractures met inclusion criteria. Median age and weight were 3 (IQR 1–6) years and 3.46 (IQR 2.5–4.78) kg. Complete healing occurred in 29/37 (78%) MIPO and 48/63 (76%) ORIF cases, for a combined outcome of 77/100 (77%). Complications occurred in 7/37 (19%) fractures repaired via MIPO and 8/63 (13%) fractures repaired via ORIF, with an overall complication rate of 15/100 (15%). Results suggest the Fixin 1.7 mm system provides acceptable outcomes comparable to existing micro-locking systems in appropriately selected cases.

Authors

Institutions

Publication Details

Journal
Veterinary and Comparative Orthopaedics and Traumatology
Published
2026-11-15
DOI
https://doi.org/10.1055/a-2993-2622
Primary Topic
Veterinary Orthopedics and Neurology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Experiences Using a 1.7 mm Locking Bone Plate System for Stabilization of Appendicular Fractures in Dogs and Cats

Matthew D. Johnson, Kian Scott Martin
Veterinary and Comparative Orthopaedics and Traumatology
Veterinary Orthopedics and Neurology
article

Experiences Using a 1.7 mm Locking Bone Plate System for Stabilization of Appendicular Fractures in Dogs and Cats

Matthew D. Johnson, Kian Scott Martin
article en

Abstract

Abstract To retrospectively evaluate the stabilization of appendicular fractures using the Fixin 1.7 mm locking plate system in dogs and cats. A review of patient medical records with traumatic appendicular fractures stabilized with the Fixin 1.7 mm locking plate was performed. Fractures were excluded due to lack of follow-up radiographs, prophylactic plating, or the use of additional plates. Data pertaining to the signalment, fracture classification, implants, evidence of radiographic healing, and limb function were recorded. Stabilization included both minimally invasive plate osteosynthesis (MIPO) and open reduction and internal fixation (ORIF) methods. Outcomes were determined from clinical and radiographic follow-ups. One hundred out of 133 evaluated fractures met inclusion criteria. Median age and weight were 3 (IQR 1–6) years and 3.46 (IQR 2.5–4.78) kg. Complete healing occurred in 29/37 (78%) MIPO and 48/63 (76%) ORIF cases, for a combined outcome of 77/100 (77%). Complications occurred in 7/37 (19%) fractures repaired via MIPO and 8/63 (13%) fractures repaired via ORIF, with an overall complication rate of 15/100 (15%). Results suggest the Fixin 1.7 mm system provides acceptable outcomes comparable to existing micro-locking systems in appropriately selected cases.

Veterinary and Comparative Orthopaedics and Traumatology
University of Florida (US)
Veterinary Orthopedics and Neurology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Experiences Using a 1.7 mm Locking Bone Plate System for Stabilization of Appendicular Fractures in Dogs and Cats — Matthew D. Johnson, Kian Scott Martin · Veterinary and Comparative Orthopaedics and Traumatology (2026) | TGRS Research Map | TGRS