Finite element analysis of different subtrochanteric osteotomy techniques in total hip arthroplasty for high hip dislocation

Aims Subtrochanteric shortening osteotomy in total hip arthroplasty (THA) for developmental dysplasia of the hip (DDH) has variable outcomes. This study evaluated the initial stability of seven different osteotomy techniques. Methods A 3D finite element model of a femur with a stem was created. Seven models simulating osteotomies with different angles (0°, 45°, 90°, -90°, 120°, -120°, z-shaped) were analyzed. Outcomes included range of motion (ROM), bone/implant stress, and osteotomy surface separation. Results The 0° model had the greatest ROM (lowest stiffness). The z-shaped and -90° designs provided the best rotational stability. Analysis of the centre of rotation showed single-symmetric models (45°, z-shaped) shifted laterally, suggesting a ‘windshield wiper’ effect, while double-symmetric models (90°, -90°, 120°, -120°) stayed aligned with the prosthesis axis. Stress patterns differed: single-symmetric models concentrated stress on the lesser trochanter, while double-symmetric models stressed the greater trochanter, with a notable ring in the -90° design. Implant stresses were similar, except in the horizontal model. The -90° and 90° models had the least osteotomy separation, unlike the 45° model. Conclusion No single osteotomy technique outperformed others in all metrics. The z-shaped and -90° designs offered the best rotational stability; the -90° and 90° designs minimized axial separation; the 45° model showed the worst ‘windshield wiper’ effect. The 120° technique provided a balanced profile with moderate rotational stability, acceptable separation, and less pronounced stress rings, representing a reasonable compromise. The choice should be guided by clinical priorities. Cite this article: Bone Joint Res 2026;15(11):1364–1373.

Authors

Institutions

Publication Details

Journal
Bone and Joint Research
Published
2026-11-16
DOI
https://doi.org/10.1302/2046-3758.1511.bjr-2026-0216.r1
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Finite element analysis of different subtrochanteric osteotomy techniques in total hip arthroplasty for high hip dislocation

huifa xu, Long Bi, Bingchen Xia, 韩一生 et al.
Bone and Joint Research
Orthopaedic implants and arthroplasty
article

Finite element analysis of different subtrochanteric osteotomy techniques in total hip arthroplasty for high hip dislocation

huifa xu, Long Bi, Bingchen Xia, 韩一生, Weilong Diwu, Zhong Wang, Yuanqi Hong, Min Yang, Qi Wu
article en

Abstract

Aims Subtrochanteric shortening osteotomy in total hip arthroplasty (THA) for developmental dysplasia of the hip (DDH) has variable outcomes. This study evaluated the initial stability of seven different osteotomy techniques. Methods A 3D finite element model of a femur with a stem was created. Seven models simulating osteotomies with different angles (0°, 45°, 90°, -90°, 120°, -120°, z-shaped) were analyzed. Outcomes included range of motion (ROM), bone/implant stress, and osteotomy surface separation. Results The 0° model had the greatest ROM (lowest stiffness). The z-shaped and -90° designs provided the best rotational stability. Analysis of the centre of rotation showed single-symmetric models (45°, z-shaped) shifted laterally, suggesting a ‘windshield wiper’ effect, while double-symmetric models (90°, -90°, 120°, -120°) stayed aligned with the prosthesis axis. Stress patterns differed: single-symmetric models concentrated stress on the lesser trochanter, while double-symmetric models stressed the greater trochanter, with a notable ring in the -90° design. Implant stresses were similar, except in the horizontal model. The -90° and 90° models had the least osteotomy separation, unlike the 45° model. Conclusion No single osteotomy technique outperformed others in all metrics. The z-shaped and -90° designs offered the best rotational stability; the -90° and 90° designs minimized axial separation; the 45° model showed the worst ‘windshield wiper’ effect. The 120° technique provided a balanced profile with moderate rotational stability, acceptable separation, and less pronounced stress rings, representing a reasonable compromise. The choice should be guided by clinical priorities. Cite this article: Bone Joint Res 2026;15(11):1364–1373.

Bone and Joint ResearchVol. 15(11)
Dalian University of Technology (CN), First Affiliated Hospital of Jiangxi Medical College (CN), Xi'an Honghui Hospital (CN), Jiangxi Provincial People's Hospital (CN), Xijing Hospital (CN), Shaanxi University of Science and Technology (CN), Xi'an Jiaotong University (CN), Northeastern University (CN), Air Force Medical University (CN)
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon