Arthroscopic Double EndoButton Adjustable‐Loop Plate Fixation for Acute Acromioclavicular Joint Dislocation

Abstract Acute acromioclavicular joint dislocation is a shoulder injury. Surgical intervention is typically recommended for Rockwood type IV to VI injuries with significant displacement. Both traditional open surgery and existing arthroscopic techniques have limitations in terms of trauma, stability, and procedural complexity. This article introduces an arthroscopic fixation technique using a double EndoButton adjustable‐loop plate. It aims to achieve anatomical reduction and sustained compressive fixation of the acromioclavicular joint through a dual‐EndoButton structure and an adjustable‐loop design. This method is relatively straightforward to perform, minimally invasive, and biomechanically sound, offering a reliable new option for the minimally invasive treatment of acute acromioclavicular joint dislocations. Preliminary clinical practice has shown favorable reduction outcomes, stable fixation performance, and potential for early rehabilitation.

Authors

Institutions

Publication Details

Journal
Arthroscopy Techniques
Published
2026-11-15
DOI
https://doi.org/10.1002/atn2.70366
Primary Topic
Shoulder and Clavicle Injuries
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Arthroscopic Double EndoButton Adjustable‐Loop Plate Fixation for Acute Acromioclavicular Joint Dislocation

Huricha Bao, Zhenxin Zheng, Shenbo Huang, Chao Qian et al.
Arthroscopy Techniques
Shoulder and Clavicle Injuries
article

Arthroscopic Double EndoButton Adjustable‐Loop Plate Fixation for Acute Acromioclavicular Joint Dislocation

Huricha Bao, Zhenxin Zheng, Shenbo Huang, Chao Qian, Hang Yuan
article en

Abstract

Abstract Acute acromioclavicular joint dislocation is a shoulder injury. Surgical intervention is typically recommended for Rockwood type IV to VI injuries with significant displacement. Both traditional open surgery and existing arthroscopic techniques have limitations in terms of trauma, stability, and procedural complexity. This article introduces an arthroscopic fixation technique using a double EndoButton adjustable‐loop plate. It aims to achieve anatomical reduction and sustained compressive fixation of the acromioclavicular joint through a dual‐EndoButton structure and an adjustable‐loop design. This method is relatively straightforward to perform, minimally invasive, and biomechanically sound, offering a reliable new option for the minimally invasive treatment of acute acromioclavicular joint dislocations. Preliminary clinical practice has shown favorable reduction outcomes, stable fixation performance, and potential for early rehabilitation.

Arthroscopy Techniques
Wenzhou Medical University (CN), Quzhou City People's Hospital (CN)
Shoulder and Clavicle Injuries
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon