Diamond Light Source: Bending-Magnet Critical Energy and Total Radiated Power at 3 GeV
This paper recomputes the principal source budgets of Diamond Light Source from its published headline parameters: a beam energy of 3.0 GeV, a stored current of 0.3 A, a circumference of 561.6 m and a dipole field of 1.4 T. The bending radius implied by those inputs is 7.15 m, giving a critical energy of 8.38 keV against a published value of 8.4 keV, an energy loss per turn of 1002 keV and a total radiated power of 301 kW against 300.0 kW published. A reference undulator of 2 cm period and 1 T peak field has parameter K of 1.87 and a fundamental at 1.56 keV, with the third and fifth harmonics reaching 4.7 keV and 7.8 keV. At the reference wavelength of 25.0 nm the diffraction-limited emittance is 1989.4 pm rad, so the stored beam, with a horizontal emittance of 2700.0 pm rad, carries a coherent fraction of about 0.737. Computed and published values agree at the level expected once lattice averages and insertion-device loads are accounted for, which makes the published parameter set an internally consistent basis for planning experiments at this facility.
Authors
- William Alexander Aldred (ORCID: https://orcid.org/0009-0000-1215-577X)
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-15
- DOI
- https://doi.org/10.5281/zenodo.24242637
- Primary Topic
- Particle Accelerators and Free-Electron Lasers
- Type
- article
- Field-Weighted Citation Impact
- 0.00