Radiographers' Adherence to Patient and Public Protection Measures from Radiation Exposure during Projection Radiography

Projection radiography is the most common diagnostic imaging tool. X-rays are one of the main types of ionising radiation. Improper use of ionizing radiation can pose a risk for healthcare workers, patients, and the general public. It is necessary to apply required precautions and adhere to protection measures when dealing with IR to decrease its potential risk. The study aimed to assess radiographers' adherence to patient and public protection measures from radiation exposure during projection radiography. A questionnaire was developed to conduct a cross-sectional study. The questionnaire had multiple dimensions, including technical procedures for reducing the exposure of patients to radiation, patient communication and clinical preparation, and public radiation protection in the workplace. The study sample included radiographers from public hospitals in Misrata, Libya. Results showed that 71.8% of participants properly collimated the radiation field, 78.8% adhered to using the correct distance between the source and image receptor, and 81.2% adhered to using correct exposure factors. On the other hand, statistical analysis showed that thyroid shields and gonad shields were not used for patients among 88.2% and 84.7% of radiographers, respectively. But 96.5% of the of sample adhered to verify that the patient is free of foreign objects, 83.5% adhered to ask female patients about pregnancy, 56.5% adhered to clearly explain the examination procedures, and 94.1% adhered to instruct the patient on the importance of remaining still. On the other hand, 55.3% of respondents indicated that periodic calibration of imaging devices was not conducted, and 65.9% indicated that there was no periodic radiation survey. However, lead aprons for non-patient personnel were not used among 45.9% of radiographers. On the other hand, 91.8% of respondents adhered to closing the room door during examinations, and 50.6% indicated there were warning signs. In Conclusion, there was significant adherence of participants to key aspects of patient radiation protection. On the other hand, there was a deficiency in adherence to certain public protection measures in the workplace, particularly in the practice of periodic calibration of devices, periodic radiation survey, and utilisation of the lead apron for non-patient personnel.

Authors

Publication Details

Journal
AlQalam Journal of Medical and Applied Sciences
Published
2026-11-15
DOI
https://doi.org/10.54361/ajmas.261132
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Radiographers' Adherence to Patient and Public Protection Measures from Radiation Exposure during Projection Radiography

Osama O. A. Almesrati
AlQalam Journal of Medical and Applied Sciences
Radiation Dose and Imaging
article

Radiographers' Adherence to Patient and Public Protection Measures from Radiation Exposure during Projection Radiography

Osama O. A. Almesrati
article en

Abstract

Projection radiography is the most common diagnostic imaging tool. X-rays are one of the main types of ionising radiation. Improper use of ionizing radiation can pose a risk for healthcare workers, patients, and the general public. It is necessary to apply required precautions and adhere to protection measures when dealing with IR to decrease its potential risk. The study aimed to assess radiographers' adherence to patient and public protection measures from radiation exposure during projection radiography. A questionnaire was developed to conduct a cross-sectional study. The questionnaire had multiple dimensions, including technical procedures for reducing the exposure of patients to radiation, patient communication and clinical preparation, and public radiation protection in the workplace. The study sample included radiographers from public hospitals in Misrata, Libya. Results showed that 71.8% of participants properly collimated the radiation field, 78.8% adhered to using the correct distance between the source and image receptor, and 81.2% adhered to using correct exposure factors. On the other hand, statistical analysis showed that thyroid shields and gonad shields were not used for patients among 88.2% and 84.7% of radiographers, respectively. But 96.5% of the of sample adhered to verify that the patient is free of foreign objects, 83.5% adhered to ask female patients about pregnancy, 56.5% adhered to clearly explain the examination procedures, and 94.1% adhered to instruct the patient on the importance of remaining still. On the other hand, 55.3% of respondents indicated that periodic calibration of imaging devices was not conducted, and 65.9% indicated that there was no periodic radiation survey. However, lead aprons for non-patient personnel were not used among 45.9% of radiographers. On the other hand, 91.8% of respondents adhered to closing the room door during examinations, and 50.6% indicated there were warning signs. In Conclusion, there was significant adherence of participants to key aspects of patient radiation protection. On the other hand, there was a deficiency in adherence to certain public protection measures in the workplace, particularly in the practice of periodic calibration of devices, periodic radiation survey, and utilisation of the lead apron for non-patient personnel.

AlQalam Journal of Medical and Applied Sciences
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon