Vesuvius AD 79: Fallout Volume from Exponential Tephra Thinning

For Vesuvius AD 79, the headline computed quantities are: proximal thickness m = 1.4; thinning constant per km = 0.055; fallout volume km3 = 9.26e-7; thickness at 100km2 m = 0.808; thickness at 1000km2 m = 0.246; thickness at 10000km2 m = 5.72e-3. A single exponential thinning law, fitted to the mapped deposit, is integrated analytically to a total fallout volume, and the result is checked against the published isopach-based estimate, with the sensitivity to the thinning constant exposed as the dominant uncertainty. The fallout volume km3 comparison for Vesuvius AD 79 pairs the computed 9.26e-7 km3 with the published 1.1 km3 reported by the fallout volume estimated by Sigurdsson and co-authors from isopach mapping of the AD 79 deposit, giving a ratio for Vesuvius AD 79 of 8.41e-7. Every single Vesuvius AD 79 number is produced by the code filed with the paper; Section 2 sets thinning constant per km at 0.055 per km, and adjusting any stated input for Vesuvius AD 79 reruns its calculation end to end. No measurement for tephra fallout volume of the AD 79 eruption is presented at Vesuvius AD 79; the budget is built from published data and stated assumptions.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-15
DOI
https://doi.org/10.5281/zenodo.24237798
Primary Topic
Geological and Geophysical Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Vesuvius AD 79: Fallout Volume from Exponential Tephra Thinning

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Geological and Geophysical Studies
article

Vesuvius AD 79: Fallout Volume from Exponential Tephra Thinning

William Alexander Aldred
article en

Abstract

For Vesuvius AD 79, the headline computed quantities are: proximal thickness m = 1.4; thinning constant per km = 0.055; fallout volume km3 = 9.26e-7; thickness at 100km2 m = 0.808; thickness at 1000km2 m = 0.246; thickness at 10000km2 m = 5.72e-3. A single exponential thinning law, fitted to the mapped deposit, is integrated analytically to a total fallout volume, and the result is checked against the published isopach-based estimate, with the sensitivity to the thinning constant exposed as the dominant uncertainty. The fallout volume km3 comparison for Vesuvius AD 79 pairs the computed 9.26e-7 km3 with the published 1.1 km3 reported by the fallout volume estimated by Sigurdsson and co-authors from isopach mapping of the AD 79 deposit, giving a ratio for Vesuvius AD 79 of 8.41e-7. Every single Vesuvius AD 79 number is produced by the code filed with the paper; Section 2 sets thinning constant per km at 0.055 per km, and adjusting any stated input for Vesuvius AD 79 reruns its calculation end to end. No measurement for tephra fallout volume of the AD 79 eruption is presented at Vesuvius AD 79; the budget is built from published data and stated assumptions.

Zenodo (CERN European Organization for Nuclear Research)
Geological and Geophysical Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon