Design Blueprint: A Sterile Robotic Sample-Transfer Chamber Sized by Air-Change, Particle-Clearance and Cycle-Time Budgets

Design blueprint derived from the source paper (DOI 10.5281/zenodo.24261313): This paper presents a calculated design for a sealed isolator chamber in the receiving laboratory where robotic manipulators move samples between return containers and analysis instruments, built on the following operating principle: samples are transferred between containers entirely by robots inside a sealed, filtered, sterilisable chamber held at protective pressure, so no human hand, glove breach or room-air excursion ever shares a volume with the exposed sample. The Clean Hands chamber clears a particle excursion by four orders of magnitude in 7 minutes against a 30 minute requirement, moves 36 items in 8.4 robotic hours, and fits the 21 day receiving window with most of it unspent. The most dangerous journey a returned sample makes is the few metres between its flight container and the laboratory's instruments, through the room where the people are; a robotic isolator removes the people from that journey entirely, and its sizing is a matter of air changes and cycle times. Sizing follows from calculated air-change, particle-clearance and cycle-time budgets, each worked in the deposited calculation script from specified parameters. The analysis is a calculated one with a civilian planetary-science purpose and no targeting or weapon use against any individual, state or terrestrial body. SIMULATED, NOT MEASURED. Status: DESIGN BLUEPRINT — SIMULATED, NOT MEASURED — NOT BUILT. All numbers are simulated values from the source paper's computation, deposited with this blueprint as compute.py and results.json. The design is a civilian planetary-science system for planetary sample return and containment, and has no targeting or weapon application. AI-use disclosure: Dave, an AI research system, assisted with the computation and drafting under the author's direction; author of record William Alexander Aldred.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-15
DOI
https://doi.org/10.5281/zenodo.24261686
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Design Blueprint: A Sterile Robotic Sample-Transfer Chamber Sized by Air-Change, Particle-Clearance and Cycle-Time Budgets

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Indoor Air Quality and Microbial Exposure
article

Design Blueprint: A Sterile Robotic Sample-Transfer Chamber Sized by Air-Change, Particle-Clearance and Cycle-Time Budgets

William Alexander Aldred
article en

Abstract

Design blueprint derived from the source paper (DOI 10.5281/zenodo.24261313): This paper presents a calculated design for a sealed isolator chamber in the receiving laboratory where robotic manipulators move samples between return containers and analysis instruments, built on the following operating principle: samples are transferred between containers entirely by robots inside a sealed, filtered, sterilisable chamber held at protective pressure, so no human hand, glove breach or room-air excursion ever shares a volume with the exposed sample. The Clean Hands chamber clears a particle excursion by four orders of magnitude in 7 minutes against a 30 minute requirement, moves 36 items in 8.4 robotic hours, and fits the 21 day receiving window with most of it unspent. The most dangerous journey a returned sample makes is the few metres between its flight container and the laboratory's instruments, through the room where the people are; a robotic isolator removes the people from that journey entirely, and its sizing is a matter of air changes and cycle times. Sizing follows from calculated air-change, particle-clearance and cycle-time budgets, each worked in the deposited calculation script from specified parameters. The analysis is a calculated one with a civilian planetary-science purpose and no targeting or weapon use against any individual, state or terrestrial body. SIMULATED, NOT MEASURED. Status: DESIGN BLUEPRINT — SIMULATED, NOT MEASURED — NOT BUILT. All numbers are simulated values from the source paper's computation, deposited with this blueprint as compute.py and results.json. The design is a civilian planetary-science system for planetary sample return and containment, and has no targeting or weapon application. AI-use disclosure: Dave, an AI research system, assisted with the computation and drafting under the author's direction; author of record William Alexander Aldred.

Zenodo (CERN European Organization for Nuclear Research)
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.