Seismic Performance Assessment of a Historical Masonry Structure Using Spectrally Matched Records of the 2023 Kahramanmaraş Earthquake and Conservation-Compatible Retrofitting Proposals: A Case Study from Diyarbakır–Hazro, Türkiye

The seismic safety assessment of registered heritage buildings requires analysis strategies that reconcile the mechanical complexity of historical masonry with the principles of minimum intervention and material compatibility. This study evaluates the seismic performance of a registered historical masonry structure located on block 157, plot 63 in the Hazro district of Diyarbakır, in the seismically active southeast of Türkiye, and develops conservation-compatible retrofitting proposals. The building, comprising a ground floor and roof level within a 17.24 m × 6.72 m rectangular plan, was discretized with three-dimensional solid finite elements in Abaqus/CAE on the basis of laser-scanning survey geometry. The seismic demand was defined by the DD-2 design spectrum of the Turkish Earthquake Hazard Map (SS = 0.477; S1 = 0.161; PGA = 0.207g; site class ZD), and the three-component records of AFAD-TADAS station 2106 from the February 6, 2023 Pazarcık (Mw 7.7) earthquake were baseline-corrected, band-pass filtered (0.10–20 Hz, Butterworth), and spectrally matched to the target spectrum using wavelet-based adjustment prior to nonlinear time history analysis. Masonry mechanical parameters were assigned per wall typology in accordance with Table 6.1 of the Turkish Guideline for the Management of Earthquake Risks in Historical Structures (TYDRYK). Modal analysis yielded closely spaced translational modes at 13.75 Hz and 14.32 Hz (T ≈ 0.07 s), consistent with the high lateral stiffness of thick-walled masonry. Under the most unfavorable load combination, maximum compressive and tensile stresses remained at 0.06 MPa and 0.07 MPa, respectively, the peak displacement was 1.05 mm, and the maximum drift ratio (0.1–0.2%) remained well below the 0.7% Controlled Damage limit. A localized capacity deficiency identified in lime-mortar brick masonry zones is resolved by the proposed interventions, after which the structure satisfies the Controlled Damage performance level under the DD-2 hazard.

Authors

Institutions

Publication Details

Journal
Black Sea Journal of Engineering and Science
Published
2026-11-15
DOI
https://doi.org/10.34248/bsengineering.2002792
Primary Topic
Masonry and Concrete Structural Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Seismic Performance Assessment of a Historical Masonry Structure Using Spectrally Matched Records of the 2023 Kahramanmaraş Earthquake and Conservation-Compatible Retrofitting Proposals: A Case Study from Diyarbakır–Hazro, Türkiye

Tahir Ateş
Black Sea Journal of Engineering and Science
Masonry and Concrete Structural Analysis
article

Seismic Performance Assessment of a Historical Masonry Structure Using Spectrally Matched Records of the 2023 Kahramanmaraş Earthquake and Conservation-Compatible Retrofitting Proposals: A Case Study from Diyarbakır–Hazro, Türkiye

Tahir Ateş
article en

Abstract

The seismic safety assessment of registered heritage buildings requires analysis strategies that reconcile the mechanical complexity of historical masonry with the principles of minimum intervention and material compatibility. This study evaluates the seismic performance of a registered historical masonry structure located on block 157, plot 63 in the Hazro district of Diyarbakır, in the seismically active southeast of Türkiye, and develops conservation-compatible retrofitting proposals. The building, comprising a ground floor and roof level within a 17.24 m × 6.72 m rectangular plan, was discretized with three-dimensional solid finite elements in Abaqus/CAE on the basis of laser-scanning survey geometry. The seismic demand was defined by the DD-2 design spectrum of the Turkish Earthquake Hazard Map (SS = 0.477; S1 = 0.161; PGA = 0.207g; site class ZD), and the three-component records of AFAD-TADAS station 2106 from the February 6, 2023 Pazarcık (Mw 7.7) earthquake were baseline-corrected, band-pass filtered (0.10–20 Hz, Butterworth), and spectrally matched to the target spectrum using wavelet-based adjustment prior to nonlinear time history analysis. Masonry mechanical parameters were assigned per wall typology in accordance with Table 6.1 of the Turkish Guideline for the Management of Earthquake Risks in Historical Structures (TYDRYK). Modal analysis yielded closely spaced translational modes at 13.75 Hz and 14.32 Hz (T ≈ 0.07 s), consistent with the high lateral stiffness of thick-walled masonry. Under the most unfavorable load combination, maximum compressive and tensile stresses remained at 0.06 MPa and 0.07 MPa, respectively, the peak displacement was 1.05 mm, and the maximum drift ratio (0.1–0.2%) remained well below the 0.7% Controlled Damage limit. A localized capacity deficiency identified in lime-mortar brick masonry zones is resolved by the proposed interventions, after which the structure satisfies the Controlled Damage performance level under the DD-2 hazard.

Black Sea Journal of Engineering and ScienceVol. 9(6)
Mardin Artuklu University (TR)
Masonry and Concrete Structural Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon