An Electrostatic Dust-Exclusion Sample Port Sized by Field Strength, Particle Charge and Deflection Budgets

Presented here is a computed design for a sample-transfer port ringed by an electrostatic curtain that charges incoming dust grains and deflects them away from the sealing surface, working on the declared principle: alternating electrodes around the port aperture impose a strong electric field; dust grains entering the field acquire charge by field charging and are deflected sideways by the same field, so the sealing face where container meets collector stays clean enough for a hermetic closure. At 361 kilovolts per metre the Charged Threshold curtain loads a three-micrometre grain with 0.7 femtocoulombs, pushes it with 215 times its Martian weight against a required factor of 50, and throws it clear of the 160 millimetre aperture within 0.7 millimetres of travel. Hermetic seals fail on dirty faces, and on a dusty planet every closure is made in a rain of abrasive grains; an electrostatic curtain is a way of sweeping the threshold without touching it, sized here from the charge a grain can carry and the force that charge buys. Sizing follows from calculated field-strength, particle-charge and deflection accounts, each carried out in the filed calculation script from stated assumptions. With no targeting or weapon use against any person, state or earthly body, this calculated analysis serves a civilian planetary-science purpose. SIMULATED, NOT MEASURED.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-15
DOI
https://doi.org/10.5281/zenodo.24261061
Primary Topic
Aerosol Filtration and Electrostatic Precipitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

An Electrostatic Dust-Exclusion Sample Port Sized by Field Strength, Particle Charge and Deflection Budgets

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Aerosol Filtration and Electrostatic Precipitation
article

An Electrostatic Dust-Exclusion Sample Port Sized by Field Strength, Particle Charge and Deflection Budgets

William Alexander Aldred
article en

Abstract

Presented here is a computed design for a sample-transfer port ringed by an electrostatic curtain that charges incoming dust grains and deflects them away from the sealing surface, working on the declared principle: alternating electrodes around the port aperture impose a strong electric field; dust grains entering the field acquire charge by field charging and are deflected sideways by the same field, so the sealing face where container meets collector stays clean enough for a hermetic closure. At 361 kilovolts per metre the Charged Threshold curtain loads a three-micrometre grain with 0.7 femtocoulombs, pushes it with 215 times its Martian weight against a required factor of 50, and throws it clear of the 160 millimetre aperture within 0.7 millimetres of travel. Hermetic seals fail on dirty faces, and on a dusty planet every closure is made in a rain of abrasive grains; an electrostatic curtain is a way of sweeping the threshold without touching it, sized here from the charge a grain can carry and the force that charge buys. Sizing follows from calculated field-strength, particle-charge and deflection accounts, each carried out in the filed calculation script from stated assumptions. With no targeting or weapon use against any person, state or earthly body, this calculated analysis serves a civilian planetary-science purpose. SIMULATED, NOT MEASURED.

Zenodo (CERN European Organization for Nuclear Research)
Aerosol Filtration and Electrostatic Precipitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
An Electrostatic Dust-Exclusion Sample Port Sized by Field Strength, Particle Charge and Deflection Budgets — William Alexander Aldred · Zenodo (CERN European Organization for Nuclear Research) (2026) | TGRS Research Map | TGRS