DEVELOPMENT AND VALIDATION OF NEW ANALYTICAL LC-MS/MS METHOD FOR THE ESTIMATION OF GENOTOXIC IMPURITIES IN SGLT2 INHIBITORS

The assessment of toxicological concentrations of possible genotoxic contaminants in drug substances was regarded as an important and challenging discipline. The International Conference and Harmonization (ICH) recommended that most pharmaceutical products be allowed to include 1.5 μg/day of a genotoxic contaminant. The goal of this study was to develop a quick and accurate method for measuring potential genotoxic impurities (PGIs) in SGLT2 inhibitors. The chromatographic conditions were appropriately optimized with the columns to achieve a decent separation and response of each impurities peak. According to International conference of Harmonization (ICH) criteria for the quantification of each impurity, method validation for LC-MS was carried out regarding specificity, the limit of detection (LOD), the limit of quantification (LOQ), linearity, accuracy (recovery), precision, and solution stability. Correlation observed in the accuracy during method validation hence method can be considered linear and accurate and can be used for testing of genotoxic impurity in SGLT2 inhibitors.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-15
DOI
https://doi.org/10.5281/zenodo.24254526
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

DEVELOPMENT AND VALIDATION OF NEW ANALYTICAL LC-MS/MS METHOD FOR THE ESTIMATION OF GENOTOXIC IMPURITIES IN SGLT2 INHIBITORS

B. Akhila, B. V. Ramana
Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
article

DEVELOPMENT AND VALIDATION OF NEW ANALYTICAL LC-MS/MS METHOD FOR THE ESTIMATION OF GENOTOXIC IMPURITIES IN SGLT2 INHIBITORS

B. Akhila, B. V. Ramana
article en

Abstract

The assessment of toxicological concentrations of possible genotoxic contaminants in drug substances was regarded as an important and challenging discipline. The International Conference and Harmonization (ICH) recommended that most pharmaceutical products be allowed to include 1.5 μg/day of a genotoxic contaminant. The goal of this study was to develop a quick and accurate method for measuring potential genotoxic impurities (PGIs) in SGLT2 inhibitors. The chromatographic conditions were appropriately optimized with the columns to achieve a decent separation and response of each impurities peak. According to International conference of Harmonization (ICH) criteria for the quantification of each impurity, method validation for LC-MS was carried out regarding specificity, the limit of detection (LOD), the limit of quantification (LOQ), linearity, accuracy (recovery), precision, and solution stability. Correlation observed in the accuracy during method validation hence method can be considered linear and accurate and can be used for testing of genotoxic impurity in SGLT2 inhibitors.

Zenodo (CERN European Organization for Nuclear Research)
Jawaharlal Nehru Technological University Anantapur (IN)
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon