Causal Peak Refinement Reduces Timing Error of a Classical R-Peak Detector Across Beat Morphologies

Abstract Purpose Classical ECG R-peak detectors are usually reported with a single aggregate score, which can hide failures on unusual beats and under noise. One such detector was evaluated by beat type, noise type and matching tolerance, and a refinement stage was tested. Methods A simplified Pan-Tompkins-style detector and a causal peak-refinement stage, which reassigns each detection to the largest absolute-amplitude sample of the 5–15 Hz band-passed signal within ± 50 ms, were implemented in Simulink. Nine MIT-BIH Arrhythmia Database records (first 120 s each) were used: five to choose settings and four held out. Noise from the MIT-BIH Noise Stress Test Database was added at 24, 12, 6 and 0 dB. Results At ± 50 ms the baseline’s mean F1 was 92.5% (88.1% on a right bundle branch block record and 63.4% on a paced record), but it was 98.2% at ± 75 ms, indicating mainly timing errors. Refinement reduced the mean absolute timing error from 25.8 ms to 6.0 ms and raised the ± 50 ms mean F1 to 98.0%. Refined F1 was equal or higher on all four held-out records. Electrode motion at 0 dB was the hardest noise (tuning records: mean F1 87.3% baseline, 91.7% refined). Refinement did not help record 207, which contains ventricular flutter and unmatched premature ventricular contractions (F1 86.3%). Conclusion Most errors under the ± 50 ms matching criterion were timing errors, and a simple causal refinement stage reduced them. The results come from nine short records and one detector, and they do not rank detectors.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-16
DOI
https://doi.org/10.21203/rs.3.rs-11728551/v1
Primary Topic
ECG Monitoring and Analysis
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Causal Peak Refinement Reduces Timing Error of a Classical R-Peak Detector Across Beat Morphologies

Sadekatul Shihab, Akib Ikbal
Research Square
ECG Monitoring and Analysis
preprint

Causal Peak Refinement Reduces Timing Error of a Classical R-Peak Detector Across Beat Morphologies

Sadekatul Shihab, Akib Ikbal
preprint en

Abstract

Abstract Purpose Classical ECG R-peak detectors are usually reported with a single aggregate score, which can hide failures on unusual beats and under noise. One such detector was evaluated by beat type, noise type and matching tolerance, and a refinement stage was tested. Methods A simplified Pan-Tompkins-style detector and a causal peak-refinement stage, which reassigns each detection to the largest absolute-amplitude sample of the 5–15 Hz band-passed signal within ± 50 ms, were implemented in Simulink. Nine MIT-BIH Arrhythmia Database records (first 120 s each) were used: five to choose settings and four held out. Noise from the MIT-BIH Noise Stress Test Database was added at 24, 12, 6 and 0 dB. Results At ± 50 ms the baseline’s mean F1 was 92.5% (88.1% on a right bundle branch block record and 63.4% on a paced record), but it was 98.2% at ± 75 ms, indicating mainly timing errors. Refinement reduced the mean absolute timing error from 25.8 ms to 6.0 ms and raised the ± 50 ms mean F1 to 98.0%. Refined F1 was equal or higher on all four held-out records. Electrode motion at 0 dB was the hardest noise (tuning records: mean F1 87.3% baseline, 91.7% refined). Refinement did not help record 207, which contains ventricular flutter and unmatched premature ventricular contractions (F1 86.3%). Conclusion Most errors under the ± 50 ms matching criterion were timing errors, and a simple causal refinement stage reduced them. The results come from nine short records and one detector, and they do not rank detectors.

Research Square
Varendra University (BD)
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon