Narrow MEMS-based tri-electrode electrostatic actuator with enhanced range and bidirectional motion using various dielectric spacer materials

A narrow width low-voltage tri-electrode electrostatic actuator is presented in this work. Simulation results show that the actuator topology can increase the controllable range of motion up to approximately four times when the extended electrode is equal to approximately 30 times the gap between moving and the fixed electrode underneath. The fabricated design helped improve the displacement range up to 37% (non-extended design) more than the conventional topology when there is a quartz spacer between the fixed electrodes. Also, the controlling voltage was reduced by 23% for the unipolar power supply mode and became 2.5 times smaller for the bipolar mode.

Authors

Institutions

Publication Details

Journal
Journal of Electrostatics
Published
2026-11-15
DOI
https://doi.org/10.1016/j.elstat.2026.104420
Primary Topic
Advanced MEMS and NEMS Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Narrow MEMS-based tri-electrode electrostatic actuator with enhanced range and bidirectional motion using various dielectric spacer materials

Byoungyoul Park, Mehdi Allameh, Cyrus Shafai, Md Wazedur Rahman
Journal of Electrostatics
Advanced MEMS and NEMS Technologies
article

Narrow MEMS-based tri-electrode electrostatic actuator with enhanced range and bidirectional motion using various dielectric spacer materials

Byoungyoul Park, Mehdi Allameh, Cyrus Shafai, Md Wazedur Rahman
article en

Abstract

A narrow width low-voltage tri-electrode electrostatic actuator is presented in this work. Simulation results show that the actuator topology can increase the controllable range of motion up to approximately four times when the extended electrode is equal to approximately 30 times the gap between moving and the fixed electrode underneath. The fabricated design helped improve the displacement range up to 37% (non-extended design) more than the conventional topology when there is a quartz spacer between the fixed electrodes. Also, the controlling voltage was reduced by 23% for the unipolar power supply mode and became 2.5 times smaller for the bipolar mode.

Journal of ElectrostaticsVol. 144
National Research Council Canada (CA), University of Manitoba (CA)
Advanced MEMS and NEMS Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon