Cavitation in a Liquid-Hydrogen Turbopump Inducer: Thermodynamic Suppression and Sigma Budgets
Cavitation in a liquid-hydrogen turbopump inducer is examined for the inducer of a rocket-engine liquid-hydrogen turbopump running near twenty kelvin with a tip speed of 120 metres per second. Principal computed quantities: cavitation number = 0.3104; dynamic pressure kPa = 511.2; vapour pressure slope kPa K = 29.09; thermal index hydrogen = 338.7; thermal index water = 1.42 times ten to the -3; thermal index ratio = 238,148.0. The governing idea, for inducer of rocket-engine liquid-hydrogen turbopump running near twenty kelvin with tip speed of 120 metres per second, runs as follows. In cryogenic liquids a growing cavity evaporates liquid and cools its own interface, lowering the local vapour pressure and throttling its growth; this thermodynamic effect suppresses cavitation relative to cold-water predictions and lets rocket inducers operate at sigma values that would destroy a water pump. Setting cavitation number at 0.3104 beside dynamic pressure kPa at 511.2 shows, for inducer of rocket-engine liquid-hydrogen turbopump running near twenty kelvin with tip speed of 120 metres per second, the scale, for inducer of rocket-engine liquid-hydrogen turbopump running near twenty kelvin with tip speed of 120 metres per second, before interpretation. Both numbers, for inducer of rocket-engine liquid-hydrogen turbopump running near twenty kelvin with tip speed of 120 metres per second, come from the cavitation in a liquid-hydrogen turbopump inducer relations. The later discussion, for inducer of rocket-engine liquid-hydrogen turbopump running near twenty kelvin with tip speed of 120 metres per second, sets cavitation number at 0.3104 against published values for inducer of rocket-engine liquid-hydrogen turbopump running near twenty kelvin with tip speed of 120 metres per second and names, for inducer of rocket-engine liquid-hydrogen turbopump running near twenty kelvin with tip speed of 120 metres per second, the input moving cavitation number at 0.3104 furthest.
Authors
- William Alexander Aldred (ORCID: https://orcid.org/0009-0000-1215-577X)
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-15
- DOI
- https://doi.org/10.5281/zenodo.24238094
- Primary Topic
- Cavitation Phenomena in Pumps
- Type
- article
- Field-Weighted Citation Impact
- 0.00