Comparative Analysis of Two Connector Designs on the Flexural Strength of CAD/CAM Milled Poly Ether-Ether Ketone Fixed Dental Prosthesis Frameworks

Background: Connectors are integral components of fixed dental prostheses (FDPs), contributing significantly to their structural integrity, stability, and longevity by ensuring effective transmission and uniform distribution of occlusal forces across the restoration. The design and geometry of connectors directly influence stress concentration and fracture resistance, particularly in modern CAD/CAM-fabricated prostheses. Therefore, this study aimed to evaluate and compare the influence of two connector designs round and triangular on the flexural strength of CAD/CAM milled 3-unit poly ether-ether ketone (PEEK) FDP frameworks. Methodology: Standardized tooth preparation was performed on a typodont model for a 3-unit FDP, followed by fabrication of a metal die. The die was scanned using a laboratory scanner, and 20 PEEK FDP frameworks were milled using CAD/CAM technology. The samples were divided into two groups: Group 1 (round connectors, n=10) and Group 2 (triangular connectors, n=10). Flexural strength was assessed using a three-point bending test on a universal testing machine. As data distribution was non-normal, statistical analysis included one-way ANOVA, Kruskal– Walli’s test, and pairwise comparisons, with significance set at p < 0.05. Results: The round connector group demonstrated higher mean flexural strength (713.27 N) compared to the triangular connector group (547.84 N), with a mean difference of 165.43 N. However, the difference was not statistically significant (p = 0.135). Conclusion: Within the limitations of this study, PEEK FDP frameworks with round connectors exhibited greater flexural strength than those with triangular connectors, although the difference was not statistically significant.

Authors

Publication Details

Journal
Journal of chemical health risks
Published
2026-11-13
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Comparative Analysis of Two Connector Designs on the Flexural Strength of CAD/CAM Milled Poly Ether-Ether Ketone Fixed Dental Prosthesis Frameworks

Neha Ranjan
Journal of chemical health risks
Dental materials and restorations
article

Comparative Analysis of Two Connector Designs on the Flexural Strength of CAD/CAM Milled Poly Ether-Ether Ketone Fixed Dental Prosthesis Frameworks

Neha Ranjan
article en

Abstract

Background: Connectors are integral components of fixed dental prostheses (FDPs), contributing significantly to their structural integrity, stability, and longevity by ensuring effective transmission and uniform distribution of occlusal forces across the restoration. The design and geometry of connectors directly influence stress concentration and fracture resistance, particularly in modern CAD/CAM-fabricated prostheses. Therefore, this study aimed to evaluate and compare the influence of two connector designs round and triangular on the flexural strength of CAD/CAM milled 3-unit poly ether-ether ketone (PEEK) FDP frameworks. Methodology: Standardized tooth preparation was performed on a typodont model for a 3-unit FDP, followed by fabrication of a metal die. The die was scanned using a laboratory scanner, and 20 PEEK FDP frameworks were milled using CAD/CAM technology. The samples were divided into two groups: Group 1 (round connectors, n=10) and Group 2 (triangular connectors, n=10). Flexural strength was assessed using a three-point bending test on a universal testing machine. As data distribution was non-normal, statistical analysis included one-way ANOVA, Kruskal– Walli’s test, and pairwise comparisons, with significance set at p < 0.05. Results: The round connector group demonstrated higher mean flexural strength (713.27 N) compared to the triangular connector group (547.84 N), with a mean difference of 165.43 N. However, the difference was not statistically significant (p = 0.135). Conclusion: Within the limitations of this study, PEEK FDP frameworks with round connectors exhibited greater flexural strength than those with triangular connectors, although the difference was not statistically significant.

Journal of chemical health risks
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon