Multicenter Comparison of Cell Block Preparation Methods Using Matched Specimen Aliquots with Low and High Cellularity

Abstract Introduction: Inadequate cellularity remains a major limitation of cell block (CB) preparation. We aimed to develop a standardized framework for the objective assessment of CB preparation protocols to optimize existing techniques and evaluate emerging technologies. Methods: Five laboratories processed matched low- and high-cellularity effusion aliquots into CBs using two HistoGel techniques (concave, butterfly) and the CytoPath Disc. Predefined serial hematoxylin and eosin (H&E) sections were evaluated for cellularity, cell distribution, morphological preservation, staining quality, and background using a 0–3 scale. An overall CB quality score (0–100) was calculated to benchmark performance. Methods were compared using one-way ANOVA with post-hoc testing to validate the model's discriminatory capacity. Results: A total of 731 H&E sections from 147 CBs were evaluated. Overall CB quality scores were comparable between the HistoGel concave (74.87 ± 10.94) and butterfly methods (75.57 ± 12.09; P = .62), whereas the CytoPath Disc yielded significantly lower scores (53.45 ± 11.56; P < .001) across both low- and high-cellularity groups. H&E section cellularity demonstrated the greatest differences between methods, particularly in CBs prepared from low-cellularity aliquots (P < .001), and was the only parameter exhibiting variability across serial sections, occurring exclusively with the CytoPath Disc method. Conclusions: This multicenter evaluation model enabled an objective comparison of CB preparation methods using matched specimen aliquots with predefined cellularity. The study validates the framework's capacity to detect protocol performance differences, providing a standardized tool for future quality assurance and the technological development in CB processing.

Authors

Publication Details

Journal
Acta Cytologica
Published
2026-11-13
DOI
https://doi.org/10.1159/acy/abjag019
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Multicenter Comparison of Cell Block Preparation Methods Using Matched Specimen Aliquots with Low and High Cellularity

Irena Srebotnik Kirbiš, Alenka Repše Fokter, Simona Gabric, Damjana Cimerman et al.
Acta Cytologica
Clinical Laboratory Practices and Quality Control
article

Multicenter Comparison of Cell Block Preparation Methods Using Matched Specimen Aliquots with Low and High Cellularity

Irena Srebotnik Kirbiš, Alenka Repše Fokter, Simona Gabric, Damjana Cimerman, Ruben Rodrigues Roque, Tinka Mohar Hajnsek, Vanessa Sofia Tavares, Saudade André, Marjeta Umek, Nina Hajdinjak, Margareta Strojan Flezar, Tadeja Dolenšek
article en

Abstract

Abstract Introduction: Inadequate cellularity remains a major limitation of cell block (CB) preparation. We aimed to develop a standardized framework for the objective assessment of CB preparation protocols to optimize existing techniques and evaluate emerging technologies. Methods: Five laboratories processed matched low- and high-cellularity effusion aliquots into CBs using two HistoGel techniques (concave, butterfly) and the CytoPath Disc. Predefined serial hematoxylin and eosin (H&E) sections were evaluated for cellularity, cell distribution, morphological preservation, staining quality, and background using a 0–3 scale. An overall CB quality score (0–100) was calculated to benchmark performance. Methods were compared using one-way ANOVA with post-hoc testing to validate the model's discriminatory capacity. Results: A total of 731 H&E sections from 147 CBs were evaluated. Overall CB quality scores were comparable between the HistoGel concave (74.87 ± 10.94) and butterfly methods (75.57 ± 12.09; P = .62), whereas the CytoPath Disc yielded significantly lower scores (53.45 ± 11.56; P < .001) across both low- and high-cellularity groups. H&E section cellularity demonstrated the greatest differences between methods, particularly in CBs prepared from low-cellularity aliquots (P < .001), and was the only parameter exhibiting variability across serial sections, occurring exclusively with the CytoPath Disc method. Conclusions: This multicenter evaluation model enabled an objective comparison of CB preparation methods using matched specimen aliquots with predefined cellularity. The study validates the framework's capacity to detect protocol performance differences, providing a standardized tool for future quality assurance and the technological development in CB processing.

Acta Cytologica
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon