Preregistration: Toroidal Log-Chirplet Transform (TLCT) versus energy-tuned DCT3D saddle-coil encoders in TokaMind on the TokaMark MAST benchmark

Preregistration of a benchmark study, posted before any confirmatory run. The study tests whether replacing TokaMind's energy-tuned DCT3D encoder on the MAST saddle-coil input (12 coils, 50 kHz) with a Toroidal Log-Chirplet Transform (TLCT) encoder lowers test error on the five MHD-activity tasks (4-1 to 4-5) of the public TokaMark benchmark. Energy tuning keeps only time frequencies up to about 500 Hz; TLCT arms encode 500 Hz to 22.5 kHz at an equal budget of 27 to 28 values per 5 ms chunk. Model, training recipe, data and scoring are otherwise fixed. Primary hypothesis (H1): across 5 paired seeds (101 to 105), TLCT with toroidal mode numbers (arm E) has lower mean TokaMark NRMSE over tasks 4-1 to 4-5 than energy-tuned DCT3D (arm A), by a one-sided paired t-test at alpha = 0.05. H2 (E versus an STFT encoder) is tested only if H1 is supported; ablations are descriptive. All 75 primary runs (arms A, B, E x 5 tasks x 5 seeds) are scored on 500 TokaMark test shots. A small validation-loss pilot and code checks run before registration are disclosed in full. Results will be published whichever way they fall.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-14
DOI
https://doi.org/10.5281/zenodo.24225813
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Preregistration: Toroidal Log-Chirplet Transform (TLCT) versus energy-tuned DCT3D saddle-coil encoders in TokaMind on the TokaMark MAST benchmark

Nicolas Brian Quiroz
Zenodo (CERN European Organization for Nuclear Research)
Magnetic confinement fusion research
article

Preregistration: Toroidal Log-Chirplet Transform (TLCT) versus energy-tuned DCT3D saddle-coil encoders in TokaMind on the TokaMark MAST benchmark

Nicolas Brian Quiroz
article en

Abstract

Preregistration of a benchmark study, posted before any confirmatory run. The study tests whether replacing TokaMind's energy-tuned DCT3D encoder on the MAST saddle-coil input (12 coils, 50 kHz) with a Toroidal Log-Chirplet Transform (TLCT) encoder lowers test error on the five MHD-activity tasks (4-1 to 4-5) of the public TokaMark benchmark. Energy tuning keeps only time frequencies up to about 500 Hz; TLCT arms encode 500 Hz to 22.5 kHz at an equal budget of 27 to 28 values per 5 ms chunk. Model, training recipe, data and scoring are otherwise fixed. Primary hypothesis (H1): across 5 paired seeds (101 to 105), TLCT with toroidal mode numbers (arm E) has lower mean TokaMark NRMSE over tasks 4-1 to 4-5 than energy-tuned DCT3D (arm A), by a one-sided paired t-test at alpha = 0.05. H2 (E versus an STFT encoder) is tested only if H1 is supported; ablations are descriptive. All 75 primary runs (arms A, B, E x 5 tasks x 5 seeds) are scored on 500 TokaMark test shots. A small validation-loss pilot and code checks run before registration are disclosed in full. Results will be published whichever way they fall.

Zenodo (CERN European Organization for Nuclear Research)
Magnetic confinement fusion research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon