Causal reliability-gated GRU sensor reconstruction for a reduced-order floating offshore wind turbine under false-data injection

Sensor reconstruction under false-data injection (FDI) is investigated on a control-oriented, reduced-order nonlinear floating offshore wind turbine inspired by the NREL 5-MW rated scale. The model combines empirical aerodynamic maps, surge–pitch platform dynamics, a single-mass drivetrain and constrained actuators. A gated recurrent unit (GRU) predicts six sensor outputs causally from trusted environmental inputs and previously applied commands. Distinct trajectories are used for training, validation, detector calibration and testing. Offline prediction-confidence weights blend received measurements and predictions after channel-wise residual detection; global detection and full-replacement variants are compared. Across 27 held-out attack/noise scenarios, channel-gated compensation reduces the dimensionless sensor-error metric by 19.02% with a mean paired rotor-speed RMSE reduction of -0.15% relative to the unprotected benchmark. Scenario reductions range from -4.04% to +6.46%, with improvement in 11 of 27 cases; near-zero mean change does not imply scenario-wise performance preservation. Channel improvements range from -3.28% for power to 78.65% for generator torque in the base condition. Reliability gating yields lower rotor-speed RMSE than full replacement in 22 of 27 matched comparisons, but superiority over fixed partial replacement or independent predictors is not established. Single-channel tests reveal limited rotor-speed attack detection: recall is 4.42% for a rotor-speed-only attack, and the clean rotor-speed false-alarm rate is 12.48%. Reliable feedback-channel protection and guaranteed post-attack recovery are not established. Vector error identities, a conditional mean-square benchmark, controller-command sensitivity, and a finite-horizon perturbation bound explain the relationship between reconstruction and regulation. The study establishes a reproducible evaluation framework for reconstruction and controller-aware assessment; its internal ablations do not separately establish advantages of the GRU architecture and the confidence-weighting rule.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-11-14
DOI
https://doi.org/10.1038/s41598-026-79503-0
Primary Topic
Smart Grid Security and Resilience
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Causal reliability-gated GRU sensor reconstruction for a reduced-order floating offshore wind turbine under false-data injection

Li‐Ying Hao, Nadir Abbas, Majid Ayoubi, Sami Ur Rehman et al.
Scientific Reports
Smart Grid Security and Resilience
article

Causal reliability-gated GRU sensor reconstruction for a reduced-order floating offshore wind turbine under false-data injection

Li‐Ying Hao, Nadir Abbas, Majid Ayoubi, Sami Ur Rehman, Nargis Bano
article en

Abstract

Sensor reconstruction under false-data injection (FDI) is investigated on a control-oriented, reduced-order nonlinear floating offshore wind turbine inspired by the NREL 5-MW rated scale. The model combines empirical aerodynamic maps, surge–pitch platform dynamics, a single-mass drivetrain and constrained actuators. A gated recurrent unit (GRU) predicts six sensor outputs causally from trusted environmental inputs and previously applied commands. Distinct trajectories are used for training, validation, detector calibration and testing. Offline prediction-confidence weights blend received measurements and predictions after channel-wise residual detection; global detection and full-replacement variants are compared. Across 27 held-out attack/noise scenarios, channel-gated compensation reduces the dimensionless sensor-error metric by 19.02% with a mean paired rotor-speed RMSE reduction of -0.15% relative to the unprotected benchmark. Scenario reductions range from -4.04% to +6.46%, with improvement in 11 of 27 cases; near-zero mean change does not imply scenario-wise performance preservation. Channel improvements range from -3.28% for power to 78.65% for generator torque in the base condition. Reliability gating yields lower rotor-speed RMSE than full replacement in 22 of 27 matched comparisons, but superiority over fixed partial replacement or independent predictors is not established. Single-channel tests reveal limited rotor-speed attack detection: recall is 4.42% for a rotor-speed-only attack, and the clean rotor-speed false-alarm rate is 12.48%. Reliable feedback-channel protection and guaranteed post-attack recovery are not established. Vector error identities, a conditional mean-square benchmark, controller-command sensitivity, and a finite-horizon perturbation bound explain the relationship between reconstruction and regulation. The study establishes a reproducible evaluation framework for reconstruction and controller-aware assessment; its internal ablations do not separately establish advantages of the GRU architecture and the confidence-weighting rule.

Scientific Reports
Kabul University (AF), King Saud University (SA), Dalian Maritime University (CN), Zhejiang University (CN)
King Saud University
Smart Grid Security and Resilience
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon