Short-term clinical and radiographic outcomes of DS PrimeTaper implants: a prospective cohort study in private practice

Abstract Objectives To assess the short-term clinical and radiographic outcomes of the DS PrimeTaper EV implant system placed in routine private practice, with a focus on implant survival, success, marginal bone loss (MBL), complications, and patient-reported outcomes (PROMs). Materials and methods This prospective observational cohort study evaluated the clinical and radiographic outcomes of DS PrimeTaper EV implants placed in two private practice settings. A total of 286 implants were placed in 154 patients and followed for an average of 14.9 months. Survival and success (MBL ≤ 0.5 mm, no signs of infection, mobility, or pain) were evaluated. Digital radiographs and PROMs questionnaires were analysed. Risk factors were explored through generalized estimating equations (GEE) and Kaplan–Meier survival analysis. Results The overall survival rate was 95.1%. Most failures (71.4%) occurred within the first six months after placement. Failure rates were higher for premolars, narrow-diameter implants, and in the presence of healing complications ( p < 0.05). Mean MBL was 0.15 ± 0.39 mm; 81.6% of implants met the success criterion. Two cases of peri-implantitis and one case of buccal MBL due to prosthetic overpressure were reported. One prosthetic fracture occurred. ISQ2, mandibular site, and reduced loading time were associated with higher success rates. PROMs showed excellent satisfaction (mean 9.0–9.4/10), though slightly lower in periodontally compromised patients. Conclusions DS PrimeTaper EV implants showed favourable short-term survival and low mean marginal bone loss in routine private practice. However, findings should be interpreted as preliminary because of the single-arm design, short follow-up, and limited number of failures. Patient satisfaction was high, and complications were rare. Clinical variables such as site, timing, and prosthetic protocol were associated with outcomes in exploratory analyses. Longer-term follow-up is warranted. Trial registration ClinicalTrials.gov NCT05500755, registered August 15, 2022.

Authors

Institutions

Publication Details

Journal
BMC Oral Health
Published
2026-11-14
DOI
https://doi.org/10.1186/s12903-026-10414-2
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Short-term clinical and radiographic outcomes of DS PrimeTaper implants: a prospective cohort study in private practice

J. Amigó-Bardají, L. Esteve-Colomina, G. Esteve-Pardo
BMC Oral Health
Dental Implant Techniques and Outcomes
article

Short-term clinical and radiographic outcomes of DS PrimeTaper implants: a prospective cohort study in private practice

J. Amigó-Bardají, L. Esteve-Colomina, G. Esteve-Pardo
article en

Abstract

Abstract Objectives To assess the short-term clinical and radiographic outcomes of the DS PrimeTaper EV implant system placed in routine private practice, with a focus on implant survival, success, marginal bone loss (MBL), complications, and patient-reported outcomes (PROMs). Materials and methods This prospective observational cohort study evaluated the clinical and radiographic outcomes of DS PrimeTaper EV implants placed in two private practice settings. A total of 286 implants were placed in 154 patients and followed for an average of 14.9 months. Survival and success (MBL ≤ 0.5 mm, no signs of infection, mobility, or pain) were evaluated. Digital radiographs and PROMs questionnaires were analysed. Risk factors were explored through generalized estimating equations (GEE) and Kaplan–Meier survival analysis. Results The overall survival rate was 95.1%. Most failures (71.4%) occurred within the first six months after placement. Failure rates were higher for premolars, narrow-diameter implants, and in the presence of healing complications ( p < 0.05). Mean MBL was 0.15 ± 0.39 mm; 81.6% of implants met the success criterion. Two cases of peri-implantitis and one case of buccal MBL due to prosthetic overpressure were reported. One prosthetic fracture occurred. ISQ2, mandibular site, and reduced loading time were associated with higher success rates. PROMs showed excellent satisfaction (mean 9.0–9.4/10), though slightly lower in periodontally compromised patients. Conclusions DS PrimeTaper EV implants showed favourable short-term survival and low mean marginal bone loss in routine private practice. However, findings should be interpreted as preliminary because of the single-arm design, short follow-up, and limited number of failures. Patient satisfaction was high, and complications were rare. Clinical variables such as site, timing, and prosthetic protocol were associated with outcomes in exploratory analyses. Longer-term follow-up is warranted. Trial registration ClinicalTrials.gov NCT05500755, registered August 15, 2022.

BMC Oral Health
University of Alicante (ES)
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon