Tool Replacement Policy for Degrading Processes with Asymmetric Specification Limits

In manufacturing industries, tool wear seems to be the most general cause behind gradual degradation of a process over time. Therefore, a systematic tool monitoring and replacement policy is the need of the hour for them. Although, a considerable amount of research work has already been done to address this issue, they primarily focus on quality characteristics having symmetric bilateral specification limits. However, in practice, often such symmetry, with respect to the target, is violated due to several practical reasons. This issue has been addressed in the present article by defining a process capability index (PCI) for degrading processes having asymmetric specification limits. Some mathematical formulations have also been suggested, based on the concepts of threshold value and maximum allowable non-conformance probability, to decide about the tool changing time, in an objective way. These should be of particular interest to production managers in taking strategic decisions regarding tool replacement. A Monte Carlo simulation study and a numerical example have also been discussed to supplement the theory developed in this article.

Authors

Publication Details

Journal
International Journal of Reliability Quality and Safety Engineering
Published
2026-11-13
DOI
https://doi.org/10.1142/s0218539326500543
Primary Topic
Advanced Statistical Process Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Tool Replacement Policy for Degrading Processes with Asymmetric Specification Limits

Moutushi Chatterjee
International Journal of Reliability Quality and Safety Engineering
Advanced Statistical Process Monitoring
article

Tool Replacement Policy for Degrading Processes with Asymmetric Specification Limits

Moutushi Chatterjee
article en

Abstract

In manufacturing industries, tool wear seems to be the most general cause behind gradual degradation of a process over time. Therefore, a systematic tool monitoring and replacement policy is the need of the hour for them. Although, a considerable amount of research work has already been done to address this issue, they primarily focus on quality characteristics having symmetric bilateral specification limits. However, in practice, often such symmetry, with respect to the target, is violated due to several practical reasons. This issue has been addressed in the present article by defining a process capability index (PCI) for degrading processes having asymmetric specification limits. Some mathematical formulations have also been suggested, based on the concepts of threshold value and maximum allowable non-conformance probability, to decide about the tool changing time, in an objective way. These should be of particular interest to production managers in taking strategic decisions regarding tool replacement. A Monte Carlo simulation study and a numerical example have also been discussed to supplement the theory developed in this article.

International Journal of Reliability Quality and Safety Engineering
Advanced Statistical Process Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon