A VALIDATED STABILITY-INDICATING RP-HPLC METHOD FOR SIMULTANEOUS DETERMINATION OF NIRMATRELVIR AND RITONAVIR IN BULK DRUG AND MARKETED PHARMACEUTICAL DOSAGE FORMS

A rapid and precise reverse phase high performance liquid chromatographic method has been developed for the validated of Nirmatrelvir and Ritonavir, in its pure form as well as in marketed pharmaceutical dosage forms. This Chromatographic Separation was carried out on Develosil C18 (4.6mm×250mm) 5µm particle size Column using a mixture of Acetonitrile and Acetate buffer (pH-4.3) was taken in the ratio of 35:65% v/v as the mobile phase at a flow rate of 1.0 mL/min, the wavelength detection was carried out at 238nm. The retention time of the Nirmatrelvir and Ritonavir was found to be 2.179, 3.610 ± 0.02 min respectively. The method produce linear responses in the concentration range of 20-60µg/ml of Nirmatrelvir and 10-30µg/ml of Ritonavir respectively. The developed method precision for the determination of assay was below 2.0%RSD. The developed method is useful in the quality control of bulk and pharmaceutical formulations.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-14
DOI
https://doi.org/10.5281/zenodo.24216351
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A VALIDATED STABILITY-INDICATING RP-HPLC METHOD FOR SIMULTANEOUS DETERMINATION OF NIRMATRELVIR AND RITONAVIR IN BULK DRUG AND MARKETED PHARMACEUTICAL DOSAGE FORMS

H. Ramana, P. Laxmi Madhuri, Singam Vinisha
Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
article

A VALIDATED STABILITY-INDICATING RP-HPLC METHOD FOR SIMULTANEOUS DETERMINATION OF NIRMATRELVIR AND RITONAVIR IN BULK DRUG AND MARKETED PHARMACEUTICAL DOSAGE FORMS

H. Ramana, P. Laxmi Madhuri, Singam Vinisha
article en

Abstract

A rapid and precise reverse phase high performance liquid chromatographic method has been developed for the validated of Nirmatrelvir and Ritonavir, in its pure form as well as in marketed pharmaceutical dosage forms. This Chromatographic Separation was carried out on Develosil C18 (4.6mm×250mm) 5µm particle size Column using a mixture of Acetonitrile and Acetate buffer (pH-4.3) was taken in the ratio of 35:65% v/v as the mobile phase at a flow rate of 1.0 mL/min, the wavelength detection was carried out at 238nm. The retention time of the Nirmatrelvir and Ritonavir was found to be 2.179, 3.610 ± 0.02 min respectively. The method produce linear responses in the concentration range of 20-60µg/ml of Nirmatrelvir and 10-30µg/ml of Ritonavir respectively. The developed method precision for the determination of assay was below 2.0%RSD. The developed method is useful in the quality control of bulk and pharmaceutical formulations.

Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon