Association of second-trimester maternal serum AFP with umbilical venous blood flow and placental morphometry: a prospective study

Background Maternal serum alpha-fetoprotein and umbilical venous Doppler measurements may reflect different aspects of fetoplacental function, but their relationship during the second trimester remains unclear. This study aimed to evaluate associations between maternal serum alpha-fetoprotein multiples of the median (AFP MoM) and umbilical venous Doppler parameters, foetal weight percentile, and placental morphometry.Methods This prospective observational study included 104 singleton pregnancies examined at 16–22 weeks. Maternal blood sampling and ultrasound/Doppler assessment were performed on the same day. Associations were evaluated using Spearman correlations and partial Spearman correlations adjusted for gestational age. Exploratory comparisons between pregnancies with AFP <2.0 MoM and AFP ≥2.0 MoM were also adjusted for gestational age. The Benjamini–Hochberg procedure controlled the false discovery rate.Results AFP MoM was available for 103 pregnancies and was not associated with foetal weight percentile or umbilical venous Doppler parameters. A weak inverse association with placental length was observed after gestational-age adjustment (partial r = −0.229; nominal p = 0.021), but it did not remain significant after false discovery rate correction (p = 0.193). In the exploratory analysis, the AFP ≥2.0 MoM group had a lower adjusted placental length (difference, −11.63 mm; 95% confidence interval, −21.10 to −2.17; nominal p = 0.017), but this difference was not significant after correction (p = 0.149).Conclusion Maternal serum AFP MoM was not associated with contemporaneous umbilical venous Doppler parameters or foetal weight percentile. Findings involving placental length were weak and should be considered exploratory.

Authors

Institutions

Publication Details

Journal
Journal of Obstetrics and Gynaecology
Published
2026-11-14
DOI
https://doi.org/10.1080/01443615.2026.2743117
Primary Topic
Pregnancy and preeclampsia studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Association of second-trimester maternal serum AFP with umbilical venous blood flow and placental morphometry: a prospective study

Zehra Tavukçuoğlu, Reyhan Ayaz Bılır, Bilge Kapudere, Sevil Çiçek et al.
Journal of Obstetrics and Gynaecology
Pregnancy and preeclampsia studies
article

Association of second-trimester maternal serum AFP with umbilical venous blood flow and placental morphometry: a prospective study

Zehra Tavukçuoğlu, Reyhan Ayaz Bılır, Bilge Kapudere, Sevil Çiçek, Özlem Demirelce, Berkay Soyupak, Yasemin Beyza Kaya Parspancı
article en

Abstract

Background Maternal serum alpha-fetoprotein and umbilical venous Doppler measurements may reflect different aspects of fetoplacental function, but their relationship during the second trimester remains unclear. This study aimed to evaluate associations between maternal serum alpha-fetoprotein multiples of the median (AFP MoM) and umbilical venous Doppler parameters, foetal weight percentile, and placental morphometry.Methods This prospective observational study included 104 singleton pregnancies examined at 16–22 weeks. Maternal blood sampling and ultrasound/Doppler assessment were performed on the same day. Associations were evaluated using Spearman correlations and partial Spearman correlations adjusted for gestational age. Exploratory comparisons between pregnancies with AFP <2.0 MoM and AFP ≥2.0 MoM were also adjusted for gestational age. The Benjamini–Hochberg procedure controlled the false discovery rate.Results AFP MoM was available for 103 pregnancies and was not associated with foetal weight percentile or umbilical venous Doppler parameters. A weak inverse association with placental length was observed after gestational-age adjustment (partial r = −0.229; nominal p = 0.021), but it did not remain significant after false discovery rate correction (p = 0.193). In the exploratory analysis, the AFP ≥2.0 MoM group had a lower adjusted placental length (difference, −11.63 mm; 95% confidence interval, −21.10 to −2.17; nominal p = 0.017), but this difference was not significant after correction (p = 0.149).Conclusion Maternal serum AFP MoM was not associated with contemporaneous umbilical venous Doppler parameters or foetal weight percentile. Findings involving placental length were weak and should be considered exploratory.

Journal of Obstetrics and GynaecologyVol. 46(1)
Istanbul Medeniyet University (TR)
Pregnancy and preeclampsia studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon