Enhancing Healthcare Quality Through Medical Laboratories: Diagnostic Accuracy and Patient Safety in Saudi Hospitals
Abstract Background: Clinical laboratory results inform most diagnostic and therapeutic decisions, so the accuracy and timeliness of testing are central to patient safety. Saudi Arabia is reorganising care into health clusters under its health sector transformation programme, and laboratory services are being consolidated, automated and accredited at pace. A synthesis of how laboratory quality affects diagnostic accuracy and patient safety in Saudi hospitals, set against the international evidence, is lacking. Objective: To review the evidence on error distribution across the total testing process, quality indicators, accreditation and quality-improvement interventions in Saudi hospital laboratories, and to compare it with Gulf Cooperation Council (GCC) and international data.Methods: A structured narrative review of PubMed-indexed literature published between 2006 and 2026 was performed. Search terms combined laboratory errors, pre-analytical phase, specimen rejection, quality indicators, turnaround time, critical values, accreditation and patient safety, with and without Saudi Arabia and GCC country terms. Twenty-nine sources were synthesised thematically using the total testing process as the organising framework.Results: International audits attribute roughly 46–68% of laboratory errors to the pre- analytical phase and 18.5–47% to the post-analytical phase, with analytical errors forming the smallest share. Saudi single-centre studies reported specimen rejection or pre-analytical error rates ranging from 0.063% of test orders in Taif to 1.28% of tests in Riyadh and 2.25% of samples in Jazan, with a higher 12.1% when cancelled and non-received requests were counted. Haemolysis was the leading cause in two studies (45.3% and 75.9% of rejections), while clotted and insufficient s pecimens dominated in a third. Emergency and inpatient areas carried the largest burden. Local interventions produced measurable gains: a Plan-Do-Study-Act project cut processing errors by 25%, total laboratory automation reduced median glucose turnaround time from 70.1 to 55.7 minutes, and point-of-care INR testing shortened clinic visits from about 180 to 30 minutes. Comparable GCC programmes reduced non-conforming specimens by 76–90%.Conclusion: Most preventable laboratory-related harm in Saudi hospitals originates outside the analytical bench, at specimen collection and at result communication. Standardised national quality indicators, phlebotomy competency programmes, electronic identification and critical-result systems, and outcome-linked accreditation monitoring offer the greatest potential gains in diagnostic accuracy and patient safety.
Authors
- Mohammed Yahya Hanin Alfaifi
- Ibrahim Ahmed Ali Khamisi
- Abdullah Ali Awaji
- Abdulhadi Mohammed Yahya Kaabi
- Ohoud Ali Almutairi
- Khalid Saad Almutairi
- Norah Saadi Alotaibi
- Mohammad Ahmad Mohammad Husseini
Institutions
- Prince Sattam Bin Abdulaziz University (SA)
- Security Forces Hospital (SA)
Publication Details
- Journal
- Power System Technology
- Published
- 2026-11-14
- DOI
- https://doi.org/10.5281/zenodo.24215720
- Primary Topic
- Clinical Laboratory Practices and Quality Control
- Type
- article
- Field-Weighted Citation Impact
- 0.00