Plume Rise at Lucky Strike on the Mid-Atlantic Ridge: Heat Flux Against a Stronger Stratification
This paper computes a hydrothermal budget for the Lucky Strike field near 37 degrees north on the Mid-Atlantic Ridge, using published observations as inputs and standard relations stated in full. The principal computed quantities are: heat flux MW = 80; buoyancy frequency per s = 0.0025; buoyancy flux m4 per s3 = 0.03329; max rise height m = 145.2; neutral buoyancy height m = 113.2; volume flux at nb m3 per s = 477.5. Each value is derived in the deposited code from the stated inputs, so the budget can be re-run with alternative published values. The results place this system quantitatively alongside other vent fields treated with the same relations, and the discussion identifies which input dominates the uncertainty of each headline number. Computed from stated assumptions and published data, not a new measurement.
Authors
- William Alexander Aldred (ORCID: https://orcid.org/0009-0000-1215-577X)
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-14
- DOI
- https://doi.org/10.5281/zenodo.24229532
- Primary Topic
- Oceanographic and Atmospheric Processes
- Type
- article
- Field-Weighted Citation Impact
- 0.00