Mixing of 350 Degree Vent Fluid With Seawater: Dilution, Diffuse Temperatures and Heat Retention

This paper computes a hydrothermal budget for a representative high-temperature vent and its surrounding diffuse outflow, using published observations as inputs and standard relations stated in full. The principal computed quantities are: seawater fraction in 28C diffuse = 0.9257; vent fraction in 28C diffuse = 0.07429; heat per kg mixture kJ = 106.6; plume anomaly at dilution 10000 K = 0.035; dilution for 0p1K anomaly = 3500; source temp excess K = 350. Each value is derived in the deposited code from the stated inputs, so the budget can be re-run with alternative published values. The results place this system quantitatively alongside other vent fields treated with the same relations, and the discussion identifies which input dominates the uncertainty of each headline number. Computed from stated assumptions and published data, not a new measurement.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-14
DOI
https://doi.org/10.5281/zenodo.24229705
Primary Topic
Geochemistry and Elemental Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Mixing of 350 Degree Vent Fluid With Seawater: Dilution, Diffuse Temperatures and Heat Retention

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Geochemistry and Elemental Analysis
article

Mixing of 350 Degree Vent Fluid With Seawater: Dilution, Diffuse Temperatures and Heat Retention

William Alexander Aldred
article en

Abstract

This paper computes a hydrothermal budget for a representative high-temperature vent and its surrounding diffuse outflow, using published observations as inputs and standard relations stated in full. The principal computed quantities are: seawater fraction in 28C diffuse = 0.9257; vent fraction in 28C diffuse = 0.07429; heat per kg mixture kJ = 106.6; plume anomaly at dilution 10000 K = 0.035; dilution for 0p1K anomaly = 3500; source temp excess K = 350. Each value is derived in the deposited code from the stated inputs, so the budget can be re-run with alternative published values. The results place this system quantitatively alongside other vent fields treated with the same relations, and the discussion identifies which input dominates the uncertainty of each headline number. Computed from stated assumptions and published data, not a new measurement.

Zenodo (CERN European Organization for Nuclear Research)
Geochemistry and Elemental Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon