Co-Produced Brine Power from Oilfield Water: Low-Temperature Binary Conversion, Flow and Parasitic-Pumping Budgets

This paper presents a computed design study of a geothermal energy system on a single stated operating principle: the hot water that oil and gas wells already produce in large volume alongside hydrocarbons — historically a disposal cost reinjected at the operator's expense — is passed through a binary unit on its way to reinjection, so the power plant's wells, pumps and water handling already exist and are already paid for. The system is an oilfield water stream of 320 kilograms per second at 112 degrees Celsius, cooled to 70 degrees Celsius through a binary unit with a 9 kelvin pinch and condensing at 32 degrees Celsius, on its existing path from separator to injection well. The design target is net electrical output after the unit's own parasitic loads, stated against the thermal power of a stream whose production cost is zero to the power project because the field produces it for other reasons. The net electrical output is 4.64 megawatts from a produced flow of 320 kilograms per second, a net conversion efficiency of 8.24 percent of the extracted thermal power of 56.3 megawatts, and an annual electricity production of 37.8 gigawatt-hours at the stated capacity factor. The purpose throughout is civilian energy supply: electricity for grids and facilities, or heat for buildings, food production and industry. Nothing in the design is optimized for any other use, and the study has no targeting or weapon application. It is a computed study; every performance figure is simulated from the stated assumptions, not measured.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-15
DOI
https://doi.org/10.5281/zenodo.24234942
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Co-Produced Brine Power from Oilfield Water: Low-Temperature Binary Conversion, Flow and Parasitic-Pumping Budgets

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
article

Co-Produced Brine Power from Oilfield Water: Low-Temperature Binary Conversion, Flow and Parasitic-Pumping Budgets

William Alexander Aldred
article en

Abstract

This paper presents a computed design study of a geothermal energy system on a single stated operating principle: the hot water that oil and gas wells already produce in large volume alongside hydrocarbons — historically a disposal cost reinjected at the operator's expense — is passed through a binary unit on its way to reinjection, so the power plant's wells, pumps and water handling already exist and are already paid for. The system is an oilfield water stream of 320 kilograms per second at 112 degrees Celsius, cooled to 70 degrees Celsius through a binary unit with a 9 kelvin pinch and condensing at 32 degrees Celsius, on its existing path from separator to injection well. The design target is net electrical output after the unit's own parasitic loads, stated against the thermal power of a stream whose production cost is zero to the power project because the field produces it for other reasons. The net electrical output is 4.64 megawatts from a produced flow of 320 kilograms per second, a net conversion efficiency of 8.24 percent of the extracted thermal power of 56.3 megawatts, and an annual electricity production of 37.8 gigawatt-hours at the stated capacity factor. The purpose throughout is civilian energy supply: electricity for grids and facilities, or heat for buildings, food production and industry. Nothing in the design is optimized for any other use, and the study has no targeting or weapon application. It is a computed study; every performance figure is simulated from the stated assumptions, not measured.

Zenodo (CERN European Organization for Nuclear Research)
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon