Integrating Vertical Green Façades to Enhance Energy Efficiency in Mixed-Use Buildings in a Highland Tropical Climate: A Mixed-Methods Study of Jos, Nigeria

Mixed-use buildings in Nigeria are among the most energy-intensive building typologies because their reinforced-concrete and glazed envelopes admit large quantities of solar heat, while unreliable grid supply forces dependence on fossil-fuelled standby generators. In Jos, a highland tropical city where an urban heat island has been documented, façade-based passive strategies remain largely unexplored. This study investigated the integration of vertical green façades (VGF) to enhance energy efficiency in the design of a mixed-use building in Jos. A mixed-methods design was adopted, combining a structured literature review, field observation and microclimate measurement at a 0.42-hectare site on Rayfield Road (Jos South), a questionnaire survey of 27 architects and allied professionals, the analysis of five case studies (World Trade Center Abuja; One Central Park, Sydney; Bosco Verticale, Milan; Parkroyal on Pickering, Singapore; and Oasia Hotel Downtown, Singapore), and whole-building energy simulation in DesignBuilder/EnergyPlus of a baseline, a VGS-integrated and a fully optimised building model. Survey respondents broadly agreed that vertical green façades reduce cooling energy (77.8%) and improve thermal comfort (77.8%), and identified technical expertise, client awareness, local performance data, building codes and maintenance as the principal barriers to adoption. Simulated annual cooling energy use intensity fell from 312 kWh/m² in the baseline model to 218 kWh/m² (−30.1%) with greenery concentrated on the south and west façades, and to 165 kWh/m² (−47.1%) when the green façade was combined with shading devices, high-performance glazing and cross-ventilation. Peak cooling load fell from 285 kW to 205 kW and 158 kW respectively. The findings demonstrate that orientation-differentiated vertical green façades, stepped planted terraces and rainwater-fed irrigation can deliver substantial cooling-energy savings in mixed-use buildings on the Jos Plateau, and support the recognition of vertical greenery as a compliance route in Nigeria's building energy-efficiency policy.

Authors

Publication Details

Journal
Knowledge Web Multidisciplinary International Journal
Published
2026-11-14
DOI
https://doi.org/10.64488/kwmij.v2i2.62
Primary Topic
Urban Heat Island Mitigation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Integrating Vertical Green Façades to Enhance Energy Efficiency in Mixed-Use Buildings in a Highland Tropical Climate: A Mixed-Methods Study of Jos, Nigeria

Henry Emusa, Abraham Atai, Rhema Emmanuel Ogwurike
Knowledge Web Multidisciplinary International Journal
Urban Heat Island Mitigation
article

Integrating Vertical Green Façades to Enhance Energy Efficiency in Mixed-Use Buildings in a Highland Tropical Climate: A Mixed-Methods Study of Jos, Nigeria

Henry Emusa, Abraham Atai, Rhema Emmanuel Ogwurike
article en

Abstract

Mixed-use buildings in Nigeria are among the most energy-intensive building typologies because their reinforced-concrete and glazed envelopes admit large quantities of solar heat, while unreliable grid supply forces dependence on fossil-fuelled standby generators. In Jos, a highland tropical city where an urban heat island has been documented, façade-based passive strategies remain largely unexplored. This study investigated the integration of vertical green façades (VGF) to enhance energy efficiency in the design of a mixed-use building in Jos. A mixed-methods design was adopted, combining a structured literature review, field observation and microclimate measurement at a 0.42-hectare site on Rayfield Road (Jos South), a questionnaire survey of 27 architects and allied professionals, the analysis of five case studies (World Trade Center Abuja; One Central Park, Sydney; Bosco Verticale, Milan; Parkroyal on Pickering, Singapore; and Oasia Hotel Downtown, Singapore), and whole-building energy simulation in DesignBuilder/EnergyPlus of a baseline, a VGS-integrated and a fully optimised building model. Survey respondents broadly agreed that vertical green façades reduce cooling energy (77.8%) and improve thermal comfort (77.8%), and identified technical expertise, client awareness, local performance data, building codes and maintenance as the principal barriers to adoption. Simulated annual cooling energy use intensity fell from 312 kWh/m² in the baseline model to 218 kWh/m² (−30.1%) with greenery concentrated on the south and west façades, and to 165 kWh/m² (−47.1%) when the green façade was combined with shading devices, high-performance glazing and cross-ventilation. Peak cooling load fell from 285 kW to 205 kW and 158 kW respectively. The findings demonstrate that orientation-differentiated vertical green façades, stepped planted terraces and rainwater-fed irrigation can deliver substantial cooling-energy savings in mixed-use buildings on the Jos Plateau, and support the recognition of vertical greenery as a compliance route in Nigeria's building energy-efficiency policy.

Knowledge Web Multidisciplinary International JournalVol. 2(2)
Urban Heat Island Mitigation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon