Leveraging Patient Data for Real‐Time Inter‐Instrument Comparison: Performance of the EWMA ‐Based PBRTQC Model on Triglyceride Measurements

BACKGROUND: Patient-based real-time quality control (PBRTQC) offers cost-effective, continuous monitoring, but its application for multi-instrument harmonization within large healthcare systems remains underexplored. This study evaluated the feasibility of using PBRTQC for inter-instrument comparison using triglyceride (TG) measurements. METHODS: From 286,855 patient TG results across two campuses of Peking University First Hospital, 245,299 valid records were extracted. PBRTQC modeling utilized the exponentially weighted moving average (EWMA) algorithm. In parallel, fresh plasma samples from 60 patients covering a wide concentration range were collected, and inter-instrument comparison was carried out on six biochemical analyzers following CLSI EP9-A2 guidelines. The relative differences derived from EWMA means were compared with those from two-level conventional internal quality control (IQC) (Levels 1 and 2) on daily, weekly, and monthly bases, using half the total allowable error (TEa = ±7%) as the acceptability threshold. RESULTS: Big-data-driven comparison yielded relative differences for five comparator analyzers against the reference system ranging from -2.05% to 2.39%. The conventional EP9-A2 comparison using 60 fresh plasma samples also showed excellent correlations (r ≥ 0.9991), with all relative differences within the predefined acceptable limit. Over daily, weekly, and monthly trends, the EWMA mean trajectories closely paralleled those of conventional IQC means. These findings indicate that EWMA-derived conclusions align well with fresh specimen assessments, providing a robust method for monitoring cross-instrument analytical comparability. CONCLUSIONS: PBRTQC using the EWMA algorithm enables continuous tracking of cross-instrument analytical performance. It serves as an effective adjunct for evaluating inter-instrument variations and strengthening multi-campus quality control.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Laboratory Analysis
Published
2026-11-13
DOI
https://doi.org/10.1002/jcla.70392
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Leveraging Patient Data for Real‐Time Inter‐Instrument Comparison: Performance of the EWMA ‐Based PBRTQC Model on Triglyceride Measurements

Yuxin Wu, 杨宏云, Jie Guan, Xinyan Yao
Journal of Clinical Laboratory Analysis
Clinical Laboratory Practices and Quality Control
article

Leveraging Patient Data for Real‐Time Inter‐Instrument Comparison: Performance of the EWMA ‐Based PBRTQC Model on Triglyceride Measurements

Yuxin Wu, 杨宏云, Jie Guan, Xinyan Yao
article en

Abstract

BACKGROUND: Patient-based real-time quality control (PBRTQC) offers cost-effective, continuous monitoring, but its application for multi-instrument harmonization within large healthcare systems remains underexplored. This study evaluated the feasibility of using PBRTQC for inter-instrument comparison using triglyceride (TG) measurements. METHODS: From 286,855 patient TG results across two campuses of Peking University First Hospital, 245,299 valid records were extracted. PBRTQC modeling utilized the exponentially weighted moving average (EWMA) algorithm. In parallel, fresh plasma samples from 60 patients covering a wide concentration range were collected, and inter-instrument comparison was carried out on six biochemical analyzers following CLSI EP9-A2 guidelines. The relative differences derived from EWMA means were compared with those from two-level conventional internal quality control (IQC) (Levels 1 and 2) on daily, weekly, and monthly bases, using half the total allowable error (TEa = ±7%) as the acceptability threshold. RESULTS: Big-data-driven comparison yielded relative differences for five comparator analyzers against the reference system ranging from -2.05% to 2.39%. The conventional EP9-A2 comparison using 60 fresh plasma samples also showed excellent correlations (r ≥ 0.9991), with all relative differences within the predefined acceptable limit. Over daily, weekly, and monthly trends, the EWMA mean trajectories closely paralleled those of conventional IQC means. These findings indicate that EWMA-derived conclusions align well with fresh specimen assessments, providing a robust method for monitoring cross-instrument analytical comparability. CONCLUSIONS: PBRTQC using the EWMA algorithm enables continuous tracking of cross-instrument analytical performance. It serves as an effective adjunct for evaluating inter-instrument variations and strengthening multi-campus quality control.

Journal of Clinical Laboratory Analysis
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Peking Union Medical College Hospital (CN), Peking University First Hospital (CN)
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon