The Safety and Feasibility of Monitoring Cardiac Arrhythmic Events Before and After Conversion From Conventional Intermittent Hemodialysis to Home Nocturnal Hemodialysis: A Pilot Study

INTRODUCTION: Patients on hemodialysis have an increased risk of sudden cardiac death and an increased cardiac arrhythmia burden due to large fluid and electrolyte shifts, especially during the long inter-dialytic period. Arrhythmia burden may be decreased on home nocturnal hemodialysis due to prolonged fluid removal and clearance. This study examined the safety and feasibility of prolonged cardiac monitoring in patients who were converting from conventional hemodialysis (12 h) to home nocturnal hemodialysis (30+ h). METHODS: Patients from a single center in Toronto, Ontario, Canada with a low cardiac risk profile, who were eligible to perform hemodialysis at home, were enrolled. Participants underwent the insertion of an implantable loop recorder and cardiac arrhythmia were monitored during conventional hemodialysis, and for 1 year after conversion to home nocturnal hemodialysis. FINDINGS: Ten participants completed the study. The average ultrafiltration rate per session during conventional hemodialysis was 6.87 mL/h/kg, and the average cardiac ejection fraction was 52.6%. There were no adverse effects associated with implantable loop recorder implantation, usage, or removal. One participant recorded three sinus bradycardia and two sinus pause events during conventional hemodialysis that resolved after conversion to home nocturnal hemodialysis. All other participants did not experience any arrhythmic events before or after conversion to home nocturnal hemodialysis. DISCUSSION: Our pilot study demonstrated a safe and feasible protocol for prolonged monitoring of cardiac arrhythmia in a stable population undergoing conversion from conventional to home nocturnal hemodialysis. Due to the small sample size, future work is required to delineate the full effect of home nocturnal hemodialysis on cardiac arrhythmia burden in patients with increased cardiac comorbidities.

Authors

Institutions

Publication Details

Journal
Hemodialysis International
Published
2026-11-13
DOI
https://doi.org/10.1111/hdi.70129
Primary Topic
Dialysis and Renal Disease Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

The Safety and Feasibility of Monitoring Cardiac Arrhythmic Events Before and After Conversion From Conventional Intermittent Hemodialysis to Home Nocturnal Hemodialysis: A Pilot Study

Christopher T. Chan, Vijay S. Chauhan, Wenqing Ye, Rebecca Noad et al.
Hemodialysis International
Dialysis and Renal Disease Management
article

The Safety and Feasibility of Monitoring Cardiac Arrhythmic Events Before and After Conversion From Conventional Intermittent Hemodialysis to Home Nocturnal Hemodialysis: A Pilot Study

Christopher T. Chan, Vijay S. Chauhan, Wenqing Ye, Rebecca Noad, Amit Kaushal, Margaret McGrath‐Chong, Gowthaman Aravindanathan, Cameron Gilbert
article en

Abstract

INTRODUCTION: Patients on hemodialysis have an increased risk of sudden cardiac death and an increased cardiac arrhythmia burden due to large fluid and electrolyte shifts, especially during the long inter-dialytic period. Arrhythmia burden may be decreased on home nocturnal hemodialysis due to prolonged fluid removal and clearance. This study examined the safety and feasibility of prolonged cardiac monitoring in patients who were converting from conventional hemodialysis (12 h) to home nocturnal hemodialysis (30+ h). METHODS: Patients from a single center in Toronto, Ontario, Canada with a low cardiac risk profile, who were eligible to perform hemodialysis at home, were enrolled. Participants underwent the insertion of an implantable loop recorder and cardiac arrhythmia were monitored during conventional hemodialysis, and for 1 year after conversion to home nocturnal hemodialysis. FINDINGS: Ten participants completed the study. The average ultrafiltration rate per session during conventional hemodialysis was 6.87 mL/h/kg, and the average cardiac ejection fraction was 52.6%. There were no adverse effects associated with implantable loop recorder implantation, usage, or removal. One participant recorded three sinus bradycardia and two sinus pause events during conventional hemodialysis that resolved after conversion to home nocturnal hemodialysis. All other participants did not experience any arrhythmic events before or after conversion to home nocturnal hemodialysis. DISCUSSION: Our pilot study demonstrated a safe and feasible protocol for prolonged monitoring of cardiac arrhythmia in a stable population undergoing conversion from conventional to home nocturnal hemodialysis. Due to the small sample size, future work is required to delineate the full effect of home nocturnal hemodialysis on cardiac arrhythmia burden in patients with increased cardiac comorbidities.

Hemodialysis International
Belfast Health and Social Care Trust (GB), University Health Network (CA), University of Calgary (CA), University of Toronto (CA)
Dialysis and Renal Disease Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon