AI- assisted compressed sensing for accelerated 1.5T shoulder MRI

Background Shoulder MRI has relatively long acquisition times. The clinical performance of AI-assisted compressed sensing (ACS) acceleration levels in 1.5-T shoulder MRI remains unclear. Objective To compare the acquisition time, image quality, and diagnostic agreement of three clinical shoulder MRI protocols using parallel imaging (PI), ACS4, and ACS8 at 1.5 T. Materials and Methods Prospectively, 158 patients with shoulder discomfort underwent three scanning protocols—the conventional Parallel imaging (PI) protocol, the ACS with a nominal acceleration factor of 4 (ACS4), and the ACS with a nominal acceleration factor of 8 (ACS8), covering four common sequences. Acquisition time, quantitative image quality parameters including True SNR, Relative SNR, Relative CNR, and edge rising distance (ERD), subjective image quality scores from three radiologists, and diagnostic agreement in an exploratory subgroup of 25 patients were assessed. Results ACS4 and ACS8 reduce the total acquisition time by approximately 29% and 45%, respectively, compared with the PI protocol while maintaining comparable image quality across evaluated sequences. ACS8 generally demonstrated higher quantitative Relative SNR/CNR values in several tissues and sequences, whereas ACS4 achieved the highest True SNR and subjective image quality scores. ERD differences were not statistically significant, and diagnostic agreement was generally high across protocols. Conclusion ACS protocols reduced acquisition time in 1.5-T shoulder MRI, although ACS8 compromised subjective image quality. ACS4 offered a more favorable balance between scanning efficiency and image quality.

Authors

Institutions

Publication Details

Journal
Technology and Health Care
Published
2026-11-14
DOI
https://doi.org/10.1177/09287329261505631
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

AI- assisted compressed sensing for accelerated 1.5T shoulder MRI

LiXue Wang, Hongpeng Dong, Yizhe Wang, Zhongyu Chen et al.
Technology and Health Care
Advanced MRI Techniques and Applications
article

AI- assisted compressed sensing for accelerated 1.5T shoulder MRI

LiXue Wang, Hongpeng Dong, Yizhe Wang, Zhongyu Chen, Wenle Hu, Zhuozhao Zheng, Junkai Wang
article en

Abstract

Background Shoulder MRI has relatively long acquisition times. The clinical performance of AI-assisted compressed sensing (ACS) acceleration levels in 1.5-T shoulder MRI remains unclear. Objective To compare the acquisition time, image quality, and diagnostic agreement of three clinical shoulder MRI protocols using parallel imaging (PI), ACS4, and ACS8 at 1.5 T. Materials and Methods Prospectively, 158 patients with shoulder discomfort underwent three scanning protocols—the conventional Parallel imaging (PI) protocol, the ACS with a nominal acceleration factor of 4 (ACS4), and the ACS with a nominal acceleration factor of 8 (ACS8), covering four common sequences. Acquisition time, quantitative image quality parameters including True SNR, Relative SNR, Relative CNR, and edge rising distance (ERD), subjective image quality scores from three radiologists, and diagnostic agreement in an exploratory subgroup of 25 patients were assessed. Results ACS4 and ACS8 reduce the total acquisition time by approximately 29% and 45%, respectively, compared with the PI protocol while maintaining comparable image quality across evaluated sequences. ACS8 generally demonstrated higher quantitative Relative SNR/CNR values in several tissues and sequences, whereas ACS4 achieved the highest True SNR and subjective image quality scores. ERD differences were not statistically significant, and diagnostic agreement was generally high across protocols. Conclusion ACS protocols reduced acquisition time in 1.5-T shoulder MRI, although ACS8 compromised subjective image quality. ACS4 offered a more favorable balance between scanning efficiency and image quality.

Technology and Health Care
Beijing Tsinghua Chang Gung Hospital (CN), Tsinghua University (CN)
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon