Design of a Highly Sensitive Surface Plasmon Resonance Sensor for Refractive-Index Detection of Shigella flexneri Contamination in Water Employing Barium Titanate and Molybdenum Disulfide

Shigella flexneri is a major waterborne pathogen, and its rapid detection in drinking water is an important public-health objective. This paper proposes a highly sensitive surface plasmon resonance (SPR) biosensor for detecting water contaminated with S. flexneri, based on a BK7 prism coated with ZnO, Ag, BaTiO 3 and a MoS 2 monolayer in the Kretschmann configuration. Four architectures are compared: BK7/Ag/sensing medium, BK7/Ag/BaTiO 3 /sensing medium, BK7/ZnO/Ag/BaTiO 3 /sensing medium, and BK7/ZnO/Ag/BaTiO 3 /MoS 2 /sensing medium. At an operating wavelength of 633 nm the refractive indices of pure and contaminated water are taken as 1.333 and 1.422 respectively, an index contrast of 0.089 RIU. The fourth architecture gives the highest sensitivity and is optimized further. With layer thicknesses of 10 nm ZnO, 30 nm Ag, 1.5 nm BaTiO 3 and a single 0.65 nm MoS 2 monolayer, a multi-objective optimization over sensitivity, minimum reflectance and figure of merit yields a sensitivity of 195.28 °/RIU, a figure of merit of 33.84 RIU -1 , a detection accuracy of 0.1733 ° -1 and a minimum reflectance of 18.17 %.

Authors

Institutions

Publication Details

Journal
Surface Review and Letters
Published
2026-11-13
DOI
https://doi.org/10.1142/s0218625x26501362
Primary Topic
Plasmonic and Surface Plasmon Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Design of a Highly Sensitive Surface Plasmon Resonance Sensor for Refractive-Index Detection of Shigella flexneri Contamination in Water Employing Barium Titanate and Molybdenum Disulfide

Malek G. Daher, Samer M. Srour, Mahmoud M. A. Eid, Marwa M. Eid
Surface Review and Letters
Plasmonic and Surface Plasmon Research
article

Design of a Highly Sensitive Surface Plasmon Resonance Sensor for Refractive-Index Detection of Shigella flexneri Contamination in Water Employing Barium Titanate and Molybdenum Disulfide

Malek G. Daher, Samer M. Srour, Mahmoud M. A. Eid, Marwa M. Eid
article en

Abstract

Shigella flexneri is a major waterborne pathogen, and its rapid detection in drinking water is an important public-health objective. This paper proposes a highly sensitive surface plasmon resonance (SPR) biosensor for detecting water contaminated with S. flexneri, based on a BK7 prism coated with ZnO, Ag, BaTiO 3 and a MoS 2 monolayer in the Kretschmann configuration. Four architectures are compared: BK7/Ag/sensing medium, BK7/Ag/BaTiO 3 /sensing medium, BK7/ZnO/Ag/BaTiO 3 /sensing medium, and BK7/ZnO/Ag/BaTiO 3 /MoS 2 /sensing medium. At an operating wavelength of 633 nm the refractive indices of pure and contaminated water are taken as 1.333 and 1.422 respectively, an index contrast of 0.089 RIU. The fourth architecture gives the highest sensitivity and is optimized further. With layer thicknesses of 10 nm ZnO, 30 nm Ag, 1.5 nm BaTiO 3 and a single 0.65 nm MoS 2 monolayer, a multi-objective optimization over sensitivity, minimum reflectance and figure of merit yields a sensitivity of 195.28 °/RIU, a figure of merit of 33.84 RIU -1 , a detection accuracy of 0.1733 ° -1 and a minimum reflectance of 18.17 %.

Surface Review and Letters
Twitter (United States) (US)
Plasmonic and Surface Plasmon Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon